Extron electronic 128, 84, 1616, 1212, 124, 168, 816, 88 manual Power, 7 - Sync termination switches

Models: 88 816 128 168 124 1212 1616 84

1 104
Download 104 pages 48.84 Kb
Page 21
Image 21
Sync termination switches

Sync termination switches

7Sync termination switches — The CrossPoint 300 matrix switchers have sync termination switches on the rear panel for inputs 1 through 4 (figure 2-7). The switches provide a way to condition non-TTL sync levels greater than

5 Vp-p, enabling the sync to be properly passed from input to selected output(s). The matrix switchers have two sets of sync termination switches; one for horizontal or combined sync and a second set for vertical sync.

15

16

 

V

V

15

 

 

 

H SYNC V SYNC

 

16

CrossPoint 300

 

 

 

 

84, 88, 124, and 128

CrossPoint 300 816, 168, 1212, and 1616

Figure 2-7 — Sync termination switches

Each switch provides the option of selecting either 510 ohms or 75 ohms.

The 75 ohms position is required only for an input with non-TTL sync, greater than 5 Vp-p. The normal position is 510 ohms.

An input that produces an out-of-sync display, a display that is rolling vertically and/or tearing horizontally, could indicate a non-TTL sync input. A device that is known to output non-TTL sync levels (greater than 5 Vp-p) should be connected to one of the inputs with sync termination switches, and the switches for that input should be set to the 75 ohm position. If you are not sure, check the specifications in the user’s manual for the input device.

Power

8AC power connector — Plug a standard IEC power cord into this connector to connect the switcher to a 100 VAC to 240 VAC, 50 or 60 Hz power source.

CrossPoint 300 Matrix Switchers • Installation

2-7