Extron electronic 84, 1616, 1212, 124, 88 Optimizing the Audio HVA Switchers, Reset, 63 - Hard reset

Models: 88 816 128 168 124 1212 1616 84

1 104
Download 104 pages 48.84 Kb
Page 64
Image 64
Performing a hard reset from the rear panel

Operation, cont’d

Performing a hard reset from the rear panel

The hard reset function restores the switcher to the original factory default settings. All user files and settings are maintained. Perform a hard reset as follows:

1.

If necessary, turn off power to the switcher.

2.

Press and hold the Reset button on the rear panel while you apply AC power

 

to the switcher (figure 3-63).

Press and hold the Reset button while you apply power to the switcher.

RESET RESET

Power

The switcher flashes the LEDs and then turns them off.

Continue to hold the Reset button until all input and output LEDs return to unlit and the RGBHV or Video and Audio LEDs turn on.

RESET Figure 3-63 — Hard reset Release the Reset button.

Figure 3-63 — Hard reset

A hard reset returns the switcher to the default (factory) firmware configuration. The switcher continues to operate using this firmware until you either cycle power, in which case the switcher begins to use the most- recently installed firmware update, or install a new firmware update.

Optimizing the Audio (HVA Switchers)

Each individual input audio level can be adjusted within a range of -18 dB to

+24 dB, so there are no noticeable volume differences between sources and for the best headroom and signal-to-noise ratio. Adjust the audio gain and attenuation as follows:

1.

Connect audio sources to all desired inputs and connect the audio outputs to

 

output devices such as audio players. See “Audio input and output (HVA

 

models only)”, in chapter 2, “Installation”. For best results, wire all of the

 

inputs and the outputs balanced.

2.

Power on the audio sources, the switcher, and the audio players.

3.

Switch among the inputs (see “Creating a configuration”, in this chapter),

 

listening to the audio with a critical ear or measuring the output audio level

 

with test equipment, such as a VU meter.

3-40 CrossPoint 300 Matrix Switchers • Operation

Page 64
Image 64
Extron electronic 84, 1616, 1212, 124 Optimizing the Audio HVA Switchers, Performing a hard reset from the rear panel, Reset