5.2TROUBLESHOOTING GUIDE CHART
The Troubleshooting Guide Chart that follows is arranged in order of the normal operational sequence. When a malfunction occurs, read down the SYMPTOM column until you reach the appropriate description for your symptom. Read the corresponding PROBABLE CAUSE and then perform the recommended procedure in the CORRECTIVE ACTION column.
SYMPTOM | PROBABLE CAUSE | CORRECTIVE ACTION |
|
|
|
No indication of power | Not plugged in | Check to ensure that power |
|
| cord is properly connected to |
|
| the machine as well as the |
|
| supply voltage. |
|
| Check the power supplied |
|
| from the outlet |
|
|
|
No indication of power, | Main Control Board, a minimum | Replace Main Control Board |
Unit is plugged in | of 2 of the 3 LED’s on this |
|
| board should be lit, if not, board |
|
| is bad |
|
| Display Panel or Cable | Inspect or replace |
| Door not making interlocks | Inspect or replace |
| Die Set not making switch | Inspect or replace |
|
|
|
No indication of power, | Main Control Board, a minimum | Replace Main Control Board |
Unit is plugged in | of 2 of the 3 LED’s on this |
|
| board should be lit, if not, board |
|
| is bad |
|
| Display Panel or Cable | Inspect or replace |
| Door not making interlocks | Inspect or replace |
| Die Set not making switch | Inspect or replace |
|
|
|
37