Samsung M9T manual Self-test execution status byte, Self-test Execution Status Values

Page 74

The total time in seconds to complete off-line data collection activity word specifies how may seconds the device requires to complete its sequence of off-line data collection activity. Valid values for this word are from 0001h to FFFFh.

Self-test execution status byte

The self-test execution status byte reports the execution status of the self-test routine.

Bits (3:0) (Percent Self-Test Remaining)

The value in these bits indicates an approximation of the percent of the self-test routine remaining until completion in ten percent increments. Valid values are 9 through 0. A value of 0 indicates the self-test routine is complete. A value of 9 means 90% of total test time remaining.

Bits (7:4) (Self-test Execution Status)

The value in these bits indicates the current Self-test Execution Status.

 

Table 8-19 Self-test Execution Status Values

 

 

Value

Description

0

The previous self-test routine completed without error or no self-test has ever been run

1

The self-test routine was aborted by the host

2

The self-test routine was interrupted by the host with a hardware or software reset

3

A fatal error or unknown test error occurred while the device was executing its self-test

 

routine and the device was unable to complete the self-test routine.

4

The previous self-test completed having a test element that failed and the test element

 

that failed is not known.

5

The previous self-test completed having the electrical element of the test failed.

6

The previous self-test completed having the servo (and/or seek) test element of the test

 

failed.

7

The previous self-test completed having the read element of the test failed.

8

The previous self-test completed having a test element that failed and the device is

 

suspected of having handling damage.

9-14

Reserved.

15

Self-test routine in progress.

Total time to complete off-line data collection

The total time in seconds to complete off-line data collection activity word specifies how many seconds the device requires completing the sequence of off-line data collection activity. Valid values for this word are from 0001h to FFFFh.

Off-line data collection capability

The following describes the definition for the off-line data collection capability bits. If the value of all of these bits is equal to zero, then this device implements no off-line data collection.

Bit 0 (EXECUTE OFF-LINE IMMEDIATE implemented bit) – If the value of this bit equals one, then the SMART EXECUTE OFF-LINE IMMEDIATE command is implemented by this device. If the value of this bit equals zero, then the SMART EXECUTE OFF-LINE IMMEDIATE command is not implemented by this device.

Bit 1 (vendor specific)

Bit 2 (abort/restart off-line by host bit) – If the value of this bit equals one, then the device shall abort all

off-line data collection activity initiated by an SMART EXECUTE OFF-LINE IMMEDIATE command upon receipt of a new command. Off-line data collection activity must be restarted by a new SMART EXECUTE OFF-LINE IMMEDIATE command from the host. If the value of this bit equals zero, the device shall suspend off-line data collection activity after an interrupting command and resume off-line

Spinpoint M9T Product Manual REV 1.0

69

Image 74
Contents M9T Product Manual Page Table of Contents Iii Read Fpdma Queued 60h Read Log Extended 2Fh Read Long 22h Table of Tables Manual Organization ScopeUser Definition Sata ReferenceDescription IntroductionKey Features Standards and Regulations Hardware RequirementsSpecifications Specification SummaryPhysical Specifications Logical ConfigurationsPerformance Specifications Power Requirements Power consumptionPower consumption RatedLinear Shock 1/2 sine pulse Environmental SpecificationsEnvironmental Specifications Rotational ShockReliability Specifications Installation Space RequirementsUnpacking Instructions MountingMounting Dimensions OrientationSata Connectivity Cable ConnectorsVentilation Computer mainboard or Serial ATA host adapter Power ManagementSATA-Bus Interface Connector HDD Power, Sata Interface, and Factory Jumper ConnectorDrive Installation DC Power Connector and SATA-Bus Interface Cable ConnectionsDC Spindle Motor Assembly Head / Disk Assembly HDABase Casting Assembly Disk Drive OperationExploded Mechanical View Voice Coil Motor and Actuator Latch Assemblies Disk Stack AssemblyHead Stack Assembly Air Filtration SystemDisk Controller Digital Signal Process and Interface ControllerDrive Electronics DDR Host Interface Control Block Buffer Control BlockFrequency Synthesizer Disk Control BlockDisk Ldpc Control Block Time Base Generator Power ManagementRead/Write IC Automatic Gain ControlAnalog Anti-Aliasing Low Pass Filter Analog to Digital Converter ADC and FIRRead Channel Servo SystemRead and Write Operations Read Caching Firmware FeaturesWrite Channel Write Caching Smart Defect ManagementAutomatic Defect Allocation 6 APMSata II Interface Sata TerminologySpinpoint M9T Product Manual REV Physical Interface Signal Summary Signal DescriptionsControl Block Register Descriptions When read When written2 I/O Register Address RegistersCommand Block Register Descriptions Command Register Ex F7h Device Register Ex F6hStatus Register Ex F7h Staggered Spin-up Disable Control Sata II Feature SETDevice Activity Signal Auto-Activate in DMA Setup FISPhy Event Counters Software Settings Preservation Sata Power ManagementCommand Code Parameters ATA Command DescriptionsCommand Table Smart Device Configuration Overlay B1h Command DescriptionsCheck Power Mode E5h Download Micro Code 92hDevice Configuration Identify data structure Word Content Flush Cache E7h, EAh extended Execute Device Diagnostics 90hDiagnostic Codes Format Track 50hContent Description Identify Device information=the fields reported in word 88 are valid EXT =Media Card Pass Through command feature set supported Word Content Description WWNIdle Immediate E1h Automatic Standby Timer PeriodsIdle E3h Read Buffer E4h Initialize Device Parameters 91hNOP 00h Read DMA C8h, 25h extendedRead Long 22h Read Multiple Command C4h, 29h extendedRead Log Extended 2Fh Read Verify Sectors 40h, 41h extended Read Native Max Address F8h, 27h extendedRead Sectors 20h, 24h extended Security Erase Prepare F3h Security Disable Password F6hRecalibrate 10h Security Erase Unit F4hSecurity Set Password data content Security Set Password F1hSecurity Erase Unit Password Word Content Security Freeze Lock F5hSeek 7xh Set Features EFhSecurity Unlock F2h 11 Set Features Register Definitions 12 Transfer Mode ValuesSet Max Address F9h, 37h extended Set Multiple Mode C6h13 Set Max Feature Register Values Sleep E6hSmart enable/disable attribute auto-save D2h 14 Smart Feature Registers ValuesSmart disable operations D9h Smart B0hSmart enable operations D8h Smart execute off-line immediate D4hSmart read data D0h 15 Device Smart Data StructureByte Bit Name Description 16 Smart Attribute Status Flags17 Smart Attribute Data List 18 Off-line Data Collection Status ValuesSelf-test execution status byte 19 Self-test Execution Status ValuesSmart write log sector D6h Smart read log sector D5hSmart return status DAh Write DMA CAh, 35h extended Standby Immediate E0hWrite Buffer E8h Write Fpdma Queued 61hWrite Multiple Command C5h, 39h extended Write Sectors 30h, 34h extendedSpinpoint M9T Product Manual REV General Information MaintenanceMaintenance Precautions HDD handling guide -Please handle HDD by side surfaces Service and Repair HDD handling guide Prevent Shocks