8.2.35 Standby (E2h)
This command causes the drive to enter Standby Mode. See 6.6.3 for the protocol. The drive may return the interrupt before the transition to Standby Mode is completed.
If the drive is already spun down, the spin down sequence is not executed.
8.2.36 Standby Immediate (E0h)
This command causes the drive to enter Standby Mode. See 6.6.3 for the protocol. The drive may return the interrupt before the transition to Standby Mode is completed.
If the drive is already spun down, the spin down sequence is not executed.
8.2.37 Write Buffer (E8h)
This command enables the host to overwrite the contents of the drive's sector buffer with any data pattern desired. See 6.6.2 for the protocol.
The Read Buffer and Write Buffer commands is synchronized within the drive so that sequential Write Buffer and Read Buffer commands access the same 512 bytes within the buffer.
8.2.38 Write DMA (CAh, 35h: extended)
This command executes in a similar manner to Write Sector(s) except the drive issues only one interrupt per command to indicate that data transfer has terminated and status is available.
Any error encountered during Write DMA execution results in the termination of data transfer. The drive issues an interrupt to indicate that data transfer has terminated and the status is available in the Error register. The error posting is the same as that for the Write Sector(s) command.
8.2.39 Write FPDMA Queued (61h)
This command is implemented according to the Serial ATA II: Extension to Serial ATA 1.0a, Revision 1.2 specification. The purpose of this command is for the host to issue a Native Command Queue (NCQ) write commands. This command allows device to reorder the command issued in a sequence of the queue. The command is returned based on the device’s determine of the location sequence.
The Spinpoint M8 drive implemented a queue depth of 32. This will allow host to issue up to 32 NCQ commands (combined read and write commands).
If the drive enters NCQ mode and a
Error information is reported according to the SATA II specification. A read Log Extended command with log page 10 is required to retrieve the error information.
Spinpoint M8 Product Manual REV 2.3 | 73 |