Mitsubishi Electronics PD-5030 Loop Out setting, To set the Loop OUT to on,  Loop OUT settings

Page 42

Loop Out setting

When this feature is set to ON, the received signal will be looped out.

Example: Setting “ON”

1.On the MAIN MENU, select “OPTION3”, then press the MENU/ENTER button.

The “OPTION3” screen appears.

2.Use the and buttons to select “LOOP OUT”.

3.To set the LOOP OUT to “ON”...

Use the  and  buttons to select “ON”.

The mode switches as follows each time the  or  button is pressed:

OFF ON

 

 

 

OPTION3

 

3 / 3

 

PREVIOUS PAGE

 

 

 

TIMER

 

 

 

 

PWR. ON MODE

 

:

LAST

BUTTON LOCK

 

:

OFF

IR REMOTE

 

:

ON

 

LOOP OUT

 

 

:

ON

 

SEL.

ADJ.

 

 

RETURN

 

 

EXIT

Information

LOOP OUT settings

ON ...... The received signal will be looped out via PC1

terminal or VIDEO1 terminal.

OFF .... The received signal will not loop out.

*Even if LOOP OUT is ON, signals won’t be sent out if POWER is being turned off.

To connect another display...

See page 10.

If the RGB/PC1 signal is present at the time the power switched on...

The RGB/PC1 input will be displayed regardless of the setting of LOOP OUT.

Restoring the factory default settings

Select “ALL RESET” under the OPTION1 menu. Note that this also restores other settings to the factory defaults.

33

Image 42
Contents Owner’s Guide Page Important Safety Instructions PD-5030/PD-6130 Precautions Important InformationRisk of Electric Shock Do not Open To avoid damage and prolong operating life Page Cleaning Safeguards Plasma Display Screen & CabinetImportant No Abrasives Introduction Features you’ll enjoy includeContents of the Package Introduction to the PD-5030/ PD-6130 Plasma MonitorsContents How to Attach Options to the Plasma Monitor Ventilation requirements for enclosure mountingPart Names and Function Front ViewRear View/ Terminal Board EXT Speaker L and RRemote Control RGB/PCBattery Installation and Replacement 5AUTO PositionOperating Range Using the wired remote control modeHandling the remote control Approx 7m/23ftInstallation Mitsubishi HD Receiver/ControllerHD-5000 Connecting Your VCR or Laser Disc Player Connecting Your DVD PlayerMonitorLink and MonitorLink Control MonitorLink Pin Configuration DVI ConnectorMonitorLink Connections External DVI Device with DVI-HDCPCable Management Video signal RGB/DVD/HD signalLoop Out ClampTo check the settings To adjust the sound volumeTo cancel the sound To adjust the size or quality of the picture automaticallyAfter the power is turned off with the off timer To set the off timerTo cancel the off timer To check the remaining timeWhen viewing videos or digital video discs Format SizesNarrow screen size 43 or Sxga Format Operation with Computer Signals Supported resolution Expand screen sizeOn-Screen Menu OSM Controls Menu OperationsVideo Settings Menu Adjusting the pictureSetting the color temperature Adjusting the color to the desired levelReducing noise in the picture  Gamma settings Making the Low Tone adjustments Adjusting the white balance  LOW Tone settings Audio settings menu Audio Settings Menu Colorview settings ColorViewAdjusting the Position, Size, Fine Picture, Picture Adj Monitor Settings MenuSetting the allocation of the audio connectors Example Setting Audio INPUT1 to VideoOption1 Settings Menu Setting the on-screen menuExample Set the BNC Input mode to Comp Setting the BNC connectorsSetting a computer image to the correct RGB select screen  BNC Input Settings Input Skip settings Setting high definition images to the suitable screen sizeSetting the Input Skip  RGB Select modesOption2 Settings Menu Resetting to the default valuesSetting the power management for computer images Peak Bright settings POWER/STANDBY indicatorSetting the picture to suit the movie Reducing burn-in of the screenOrbiter settings Orbiter Function settingsSetting the time Inverse SettingsSetting the time for INVERSE/WHITE ExampleGray Level settings Setting the screen size for S1/S2 video inputSoft Focus settings Soft FocusPLUG/PLAY settings Setting the signal and black level for DVI signalS1/S2 settings Black Level settings Present Time settings Option3 Settings MenuUsing the timer Present Time To reset the program Setting the power on mode Program Timer settings  Special characters in the Program Timer screen Button Lock settings Enabling/disabling remote control wireless transmission PWR. on Mode settings  IR Remote settingsTo set the Loop OUT to on Loop Out setting Loop OUT settings  To connect another displaySetting the language for the menus Language Settings MenuColor System Settings Menu Setting the video signal formatConnections RS-232C ControlApplication Communication ParametersTroubleshooting Symptom Checks RemedyPage Specifications PD-5030 SignalsSpecifications PD-6130 Table of Signals Supported Supported resolutionComputer input signals supported by this system Page Mitsubishi Plasma Display Panel Limited Warranty Declaration of Conformity