Honeywell HRDE4X4 manual Alarm, Out, Video OUT, Vga, Switches

Page 16

Table 2-1 Rear Panel Connections (Cont’d)

Connector Description

SENSOR IN Connect to external alarm sensor devices to signal the DVR to react to events. Four sensors can be connected to the equipment sensor 1–4 dedicated to Video channel 1–4 respectively. Simple On/Off switching of sensor inputs 1–4, normal open (NO) and ground connected to input starts recording or normal close (NC) and ground connected to input stops recording (see Recording Mode, page 15 to program sensor recording).

Connect two wires to operate a sensor input correctly to the Terminal block on the rear panel of the HRDE4X4. One ground wire between the external device and to the HRDE4X4 ensures the ground reference voltage is identical. This line connects to the terminal block G input. Connect the other wire to be used to trigger the record condition to the sensor input 14connection on the terminal block.

Sensor Input

1 G 2 G 3 G 4 G

OUT

Connections

 

 

In 1

In 2

In 3

In 4

ALARM

 

GND 1 GND 2 GND 3

GND 4

 

 

ALARM

Connect to an external alarm device. On/off switching using an internal

OUT

relay, 0.5A/125V, 1A/30V. The relay is open when not triggered. The relay

 

can be triggered to close by either motion or a sensor input, if enabled in

 

the Recording Setup menu.

 

 

 

VIDEO IN

Connect NTSC or PAL camera coaxial outputs (up to 4) to the BNC Video

 

In connectors.

 

 

Caution Do not mix NTSC and PAL cameras.

 

 

 

 

VIDEO OUT

Connect to a monitor.

 

 

 

 

RS-232

For engineering use only.

 

 

 

 

VGA

Connect to a VGA monitor.

 

 

Note When using a VGA monitor, make sure you set the VGA switch to

 

ON and power reset the unit (turn unit off then on).

 

 

 

SWITCHES

 

 

 

 

PAL

Set to the ON position when PAL cameras are connected.

 

Note When you change the position of the PAL switch, reboot the DVR

 

to apply the new setting.

 

 

 

VGA

Set to the ON position when a VGA monitor is connected.

 

Note When you change the position of the VGA switch, reboot the DVR

 

to apply the new setting. When VGA is enabled, the video out

 

connector (composite) is disabled. Also when the Video Out is

 

enabled, the VGA is disabled.

 

 

 

DC 12V

Apply 12 VDC using the DC switching adapter supplied.

 

 

 

 

 

 

Rev 2.00

8

Document 900.0399

 

 

03/06

Image 16
Contents HRDE4X4 Digital Video Recorder User GuideIssue Date Revisions RevisionsFCC Compliance Statement Weee Waste Electrical and Electronic Equipment Contents Appendix a DVR Firmware Upgrade RAS ConfigurationAppendix D Specifications Figures Figure A-1 Engineering Mode Introduction FeaturesTechnical Overview Important Safeguards Dispose of used batteries according to the instructions Page Before You Begin DVR Unit InstallationUnpack Everything Typical DVR Installation Setting Unit for Ntsc or PALConnecting Peripheral Equipment Rear Panel Connections Connector DescriptionAlarm SwitchesOUT VideoConnecting the Power Cord Rev Document 03/06 DVR Configuration Front Panel LEDs and ControlsUSB Port Initial Setup Menu StructureLive Mode Recording Mode Motion Zones Motion Zone Setup Screen Recording SchedulesSetting System Parameters Admin PasswordDate Format SET Date & TimeDVR ID Setup Screen Setting Network Parameters Controlling a PTZ CameraRemote Access PortBandwidth SavingNetwork Setup Fields Cont’d Ddns ServerName Send E-MAIL Mail AddressStorage Setup DhcpOverwrite Storage Setup Fields DescriptionFormat Saving Setup 14 Save Setup ScreenFront Panel Operation Live Viewing WindowButton Functions in Live Viewing Window Search WindowButton Description Event Search Event Search ScreenTime-Line Search Event Search List ScreenGo To Search Time-line Search ScreenGo Last Search Go First SearchLog List Search Archive Search 10 Archive Search ScreenPlay Mode Highlighted channel Network ModePress to launch the archiving function Archiving Images or Video onto the Hard Drive Archiving VideoTransferring Still Images or Video onto USB 15 Archive Menu Screen Rev Document 03/06 Installing the RAS Program RAS InstallationMinimum PC Requirements Choose Destination Location Live Viewing RAS OperationLive Viewing Interface Live Viewing Interface Controls Live Viewing Interface Controls Cont’d Search and Playback Interface Search and Playback ViewingInterface Control Description Search and Playback Interface Controls Search and Playback Interface Controls Cont’d Back Up a Video Clip in AVI Format Main User Interface with Back Up Times MarkedAVI Backup Window RAS Configuration General SetupSite Setup Event SetupEvent Search Setup Event Search MenuRecord Menu Settings Setting Operation Record MenuDisk Menu Video MenuAbout Menu Copy Firmware Upgrade to USB Stick DVR Firmware UpgradeStart Engineering Mode Upgrading Using USB Stick Verifying Software InstallationFigure B-1 Ffdshow Video Decoder Configuration Playing AVI Archive ClipsRev Document 03/06 Remote Control Operation Optional ItemsConfiguring Multiple Units for Remote Control Press to select the remote unitSpecifications Table D-1 Technical Specifications VideoConnectors Inputs, OutputsStorage Table D-1 Technical Specifications Cont’dGeneral Page Video Systems