Extron electronic DDS 402 manual Host-to-Scaler Instructions, Scaler Error Responses

Page 37

Host-to-Scaler Instructions

The scaler accepts SIS (Simple Instruction Set) commands through the

Remote port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each scaler response to an SIS command ends with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.

Scaler Error Responses

When the scaler receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the scaler is unable to perform the command because the command is invalid or contains invalid parameters, the scaler returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number (too large)

E13 — Invalid value (out of range)

E17 — Illegal command for this signal type

Using the Command/Response Table

The command/response table begins on the next page. Except for the horizontal and vertical filter settings, upper or lower case letters are acceptable in the command field. The table below shows the hexadecimal equivalent of each ASCII command. Symbols, defined on page 4-2, are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table.

ASCII to HEX Conversion Table

Space

With the exception of the horizontal and vertical filtering (D and d) commands, the SIS commands are not case sensitive.

Digital Display Scaler • Programmer’s Guide

4-5

Image 37
Contents Digital Display Scaler DDSConsignes de Sécurité Français Safety Instructions EnglishSicherheitsanleitungen Deutsch Instrucciones de seguridad EspañolQS-1 Rear panel video outputsQuick Start DDS 402, cont’d Default display cycleMain menu Input menu QS-2Output menu Memory Presets menuQS-3 Picture Adjustments menu Advanced Configuration menuExecutive Mode menu Exit menuTable of Contents Table of Contents, cont’d Digital Display Scaler Table of Contents Iii Iv Digital Display Scaler Table of Contents One About this Manual Introductiontroduction, cont’dAbout the Scaler Digital Display Scaler IntroductionFeatures Introduction, cont’d Digital Display Scaler Introduction Introduction, cont’d Two Installation Overview Installationstallation, cont’dMounting the Scaler Cabling and Rear Panel ViewsVideo output connections Video input connectionsConfiguration Installation, cont’dPower connection RS-232 connectionThree Operationeration, cont’d Front Panel Controls and IndicatorsFreeze button Input buttonsAdjustment knobs Picture adjustment buttonsLCD display Menu control buttonsOperation, cont’d PowerFront Panel Operations Button iconsInput Configuration menu ConfigurationOutput Configuration menu Pixel Phase submenuInput #2 submenu Resolution 50 Hz 56 Hz 60 Hz 75 Hz 85 Hz Lock at 50/60 Hz Resolution and refresh rates submenuOutput Signal submenu Sync Polarity submenuErase Presets submenu Save Presets submenuRGB Delay submenu Blue Mode submenuEdge Smoothing submenu Test Pattern submenuReset submenu Picture adjustmentsAdjust knobs have no mechanical limits to their rotation Front panel security lockout executive modeOptimizing the Video Setting up a DVD sourceFour Digital Display Scaler Programmer’s Guide SymbolsScaler-Initiated Messages Presets RGB delayProgrammer’s Guide, cont’d Test patternUsing the Command/Response Table Scaler Error ResponsesHost-to-Scaler Instructions Command Ascii Command Response Additional description Command/response table for SIS commandsCommand/response table for SIS commands cont’d Test pattern Command Ascii Command Response Command/response table for special function SIS commandsProgrammer’s Guide, cont’d Five Using the control program Installing the softwareControl Software for Windows Digital Display Scaler Scaler SoftwareControl program I/O configuration window Using the help programScaler Software, cont’d Using the softwareButton Label Generator AAppendix a Digital Display Scaler Reference Information SpecificationsIncluded parts Part NumbersSuggested part Included parts Part numberReference Information, cont’d Firmware Upgrade InstallationU24 U60 U68U67 Button Labels Installing labels in the scaler’s buttonsFCC Class a Notice Extron’s Warranty Extron Electronics, USA