Runco XP-OPAL65, XP-OPAL50 Description, Features and Benefits, Key Features and Benefits

Page 17

Introduction

The CinemaWall Flat-Panel Plasma Display Monitor takes picture quality to a whole new level, boasting our brightest picture, best contrast ratio, deepest black levels and most spot-on high definition colorimetry ever! In addition, sophisticated 16-bit digital video processing, a new milestone, results in 4096 steps of graduation for seamless images completely devoid of the primitive “solarization” and “stair stepping” characteristics previously plaguing digital flat panel displays.

The CinemaWall features all of the Runco technologies you have come to expect from the World's Finest Home Theater Products. Discrete, multiple aspect ratio control includes VirtualWide™ for viewing 4:3 content in widescreen without appreciable picture degradation, as well as ISF(ccc) calibration modes to easily maintain ISF standards. The automation interface includes RS-232 control with discrete aspect ratio, input and power on/off selection.

The CinemaWall not only represents a leap forward in high definition flat-panel technology, but our engineering advances in plasma design ensure that it will enjoy a long life in any installation, with operation extending to as much as 60,000 hours. At less than 4-1/4 inches thin, the CinemaWall provides unlimited installation flexibility as well.

The CinemaWall offers these key features and benefits:

16:9 Native Resolution: 1920 x 1080

Models XP-OPAL50 and XP-OPAL65 feature Runco-exclusive Optical Path Alignment (OPAL) technology, which delivers extreme glare reduction and enhanced contrast for high ambient light environments

Multiple Aspect Ratios with VirtualWide™ Mode

Less than 4-1/4 inches thin

High-altitude compliant to 9,000 feet

Exceptional detail and artifact-free video enhancement

ViVix™ video processing with 3:2 film detection circuitry

1.3

Description, Features and Benefits

Key Features and Benefits

CinemaWall Installation/Operation Manual

3

Image 17
Contents XP-65 XP-50Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Specifications Maintenance and TroubleshootingAppendix A. Default Settings OperationList of Figures List of Figures Xiv Introduction Carriage return must be used after each command or stringAbout This Manual Target AudienceCertain features Using This ManualSignificance. They also provide supplemental information Degrade performance or cause a malfunctionKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50 and XP-OPAL50 CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand XP-50 / XP-OPAL50 XP-65 / XP-OPAL65 ConnectorsPower Input Surround button CinemaWall Remote ControlControls and Functions Other surfaces InstallationRemote Control Installation must be performed by a qualified custom video Quick SetupInstallation specialist Step Procedure For Details, refer toInstallation Considerations Ventilation Ambient LightOther Considerations Connections to Connecting SourceCinemaWall Components toDVD Analog RGB Connections Connector Pin Assignments Connecting External Speakers OptionalRS-232 Controller ConnectionAC Power Connection Operation Turning on the Power Changing the OSD LanguageSetting the Day and Time Setting the Computer Display Properties Aspect ratio selection is saved independently for each input Selecting an Input Source Changing the Aspect Ratio149 169Source image horizon 43 431 linearly scalesPlayed at the left and right Edges of the screenActivating PIP Swapping the Main PIP Images Using Picture-In-Picture PIPSelecting a PIP Target Using the On-Screen MenusScreen or Input Source Changing the PIP Window PositionPOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness POS./SIZE CinemaWall memorizes position and size settings separatelyFrequency is 108 MHz or greater Options menu refer to page 50 is set to OnSound Or 1080p and the Aspect Ratio is set to 169 refer toSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Order to activate multi-display mode, you must first set Refer to Changing the OSD Language onOn hides joints between displays C D Insert cannot be used when Transparency is set to on Transparency cannot be used when Insert is set to onPresent Time Setup Refer to Setting the Day and Time on Command Timer refer toDVD3 Operation Refer to Return ChangeCurrently active Level see belowSome cases, power is transmitted to the slot when When using multiple displays such as in a video wall RuncoMULTI-DISPLAY is active Picture menu is set to WarmOn page 21, the Clock Display setting has no effect Using Digital ZoomDuring the delay period, the power indicator flashes green Operation Cleaning Maintenance and TroubleshootingCleaning the Display Panel Body and Remote Control Cleaning the ScreenSymptom Possible Causes Solution Troubleshooting TipsCommand 3 bytes Parameter 6 bytes Command 3 bytes Parameter 3 bytesSerial Communications ExamplesHex Description Serial CommandsDamzoom IMSPC1 SSCFNC0 VDO VWBGCT-30 Serial Communications CinemaWall Specifications SpecificationsCinemaWall Dimensions 12.31 Supported Timings Supported Signal Timings by Input Specifications Table A-1. Runco Factory Default Settings for CinemaWall Appendix A. Default SettingsDefault Settings Page 020-0970-01 Rev. a September