Runco XP-OPAL65 43 431 linearly scales, Source image horizon, Played at the left and right, 432

Page 39

Operation

Table 4-1. Aspect Ratio Settings (continued)

Aspect Ratio Setting

 

(Note)

 

 

Input Image -> Displayed Image

Description

All Aspect

All Aspect

 

= ON

= OFF

 

 

 

4:3 (4:3(1)) linearly scales

 

 

the source image horizon-

 

 

tally and vertically to fill a 4:3

 

 

screen. Side panels are dis-

4:3(1)

4:3

played at the left and right

 

 

edges of the screen.

 

 

4:3(2) displays a 16:9

 

 

source image in its original

4:3(2)

aspect ratio and masks the

 

 

left and right sides.

 

 

FILL is similar to

 

 

VIRTUALWIDE2 (see

FILL

FILL

above), but employs a lin-

ear, horizontal stretch.

 

 

Note: This setting is not

 

 

available with SD signals.

 

 

LETTERBOX

 

 

(LETTERBOX1) scales

 

 

(zooms in on) a 4:3 image

 

 

linearly (by the same

 

 

amount on all sides) to fill a

 

 

16:9 display, cropping the

LETTER-

LETTER-

top and bottom of the

BOX1

BOX

image.

16:9 images are vertically scaled by a factor of approximately 1.33, but the width is unchanged.

LETTER-

LETTERBOX2 scales

BOX2

 

(zooms in on) a 16:9 image

 

 

linearly (by the same

 

 

amount on all sides) to fill a

 

 

16:9 display, cropping the

 

 

image on all sides.

Note: To make all of the aspect ratio selections listed here available to the viewer, set All Aspect in the OPTIONS menu (described on page 51) to On.

CinemaWall Installation/Operation Manual

25

Image 39
Contents XP-65 XP-50Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. Default SettingsList of Figures List of Figures Xiv Target Audience Carriage return must be used after each command or stringIntroduction About This ManualDegrade performance or cause a malfunction Using This ManualCertain features Significance. They also provide supplemental informationKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50 and XP-OPAL50 Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand XP-50 / XP-OPAL50 XP-65 / XP-OPAL65 ConnectorsPower Input Surround button CinemaWall Remote ControlControls and Functions Installation Remote ControlOther surfaces Step Procedure For Details, refer to Quick SetupInstallation must be performed by a qualified custom video Installation specialistInstallation Considerations Ventilation Ambient LightOther Considerations Components to Connecting SourceConnections to CinemaWallDVD Analog RGB Connections Connection Connecting External Speakers OptionalConnector Pin Assignments RS-232 ControllerAC Power Connection Turning on the Power Changing the OSD Language Setting the Day and TimeOperation Setting the Computer Display Properties Aspect ratio selection is saved independently for each input Selecting an Input Source Changing the Aspect Ratio149 169Edges of the screen 43 431 linearly scalesSource image horizon Played at the left and rightActivating PIP Swapping the Main PIP Images Using Picture-In-Picture PIPChanging the PIP Window Position Using the On-Screen MenusSelecting a PIP Target Screen or Input SourcePOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness POS./SIZE CinemaWall memorizes position and size settings separatelyFrequency is 108 MHz or greater Options menu refer to page 50 is set to OnSound Or 1080p and the Aspect Ratio is set to 169 refer toSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Order to activate multi-display mode, you must first set Refer to Changing the OSD Language onOn hides joints between displays C D Insert cannot be used when Transparency is set to on Transparency cannot be used when Insert is set to onPresent Time Setup Refer to Setting the Day and Time on Command Timer refer toDVD3 Operation Refer to Return ChangeCurrently active Level see belowPicture menu is set to Warm When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when MULTI-DISPLAY is activeUsing Digital Zoom During the delay period, the power indicator flashes greenOn page 21, the Clock Display setting has no effect Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsExamples Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes Serial CommunicationsHex Description Serial CommandsDamzoom IMSPC1 SSCFNC0 VDO VWBGCT-30 Serial Communications CinemaWall Specifications SpecificationsCinemaWall Dimensions 12.31 Supported Timings Supported Signal Timings by Input Specifications Table A-1. Runco Factory Default Settings for CinemaWall Appendix A. Default SettingsDefault Settings Page 020-0970-01 Rev. a September