Runco XP-OPAL50, XP-OPAL65 operation manual Default Settings

Page 84

A-2

CinemaWall Installation/Operation Manual

Image 84
Contents XP-50 XP-65Page RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Maintenance and Troubleshooting SpecificationsAppendix A. Default Settings OperationList of Figures List of Figures Xiv Carriage return must be used after each command or string IntroductionAbout This Manual Target AudienceUsing This Manual Certain featuresSignificance. They also provide supplemental information Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-50 and XP-OPAL50 Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand Connectors XP-50 / XP-OPAL50 XP-65 / XP-OPAL65Power Input CinemaWall Remote Control Surround buttonControls and Functions Installation Remote ControlOther surfaces Quick Setup Installation must be performed by a qualified custom videoInstallation specialist Step Procedure For Details, refer toInstallation Considerations Ambient Light VentilationOther Considerations Connecting Source Connections toCinemaWall Components toDVD Analog RGB Connections Connecting External Speakers Optional Connector Pin AssignmentsRS-232 Controller ConnectionAC Power Connection Turning on the Power Changing the OSD Language Setting the Day and TimeOperation Setting the Computer Display Properties Selecting an Input Source Changing the Aspect Ratio Aspect ratio selection is saved independently for each input169 14943 431 linearly scales Source image horizonPlayed at the left and right Edges of the screenUsing Picture-In-Picture PIP Activating PIP Swapping the Main PIP ImagesUsing the On-Screen Menus Selecting a PIP TargetScreen or Input Source Changing the PIP Window PositionPOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness CinemaWall memorizes position and size settings separately POS./SIZEOptions menu refer to page 50 is set to On Frequency is 108 MHz or greaterOr 1080p and the Aspect Ratio is set to 169 refer to SoundSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Refer to Changing the OSD Language on Order to activate multi-display mode, you must first setOn hides joints between displays C D Transparency cannot be used when Insert is set to on Insert cannot be used when Transparency is set to onCommand Timer refer to Present Time Setup Refer to Setting the Day and Time onDVD3 Operation Return Change Refer toLevel see below Currently activeWhen using multiple displays such as in a video wall Runco Some cases, power is transmitted to the slot whenMULTI-DISPLAY is active Picture menu is set to WarmUsing Digital Zoom During the delay period, the power indicator flashes greenOn page 21, the Clock Display setting has no effect Operation Maintenance and Troubleshooting CleaningCleaning the Display Panel Body and Remote Control Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionCommand 3 bytes Parameter 3 bytes Command 3 bytes Parameter 6 bytesSerial Communications ExamplesSerial Commands Hex DescriptionDamzoom IMSPC1 SSCFNC0 VDO VWBGCT-30 Serial Communications Specifications CinemaWall SpecificationsCinemaWall Dimensions 12.31 Supported Timings Supported Signal Timings by Input Specifications Appendix A. Default Settings Table A-1. Runco Factory Default Settings for CinemaWallDefault Settings Page 020-0970-01 Rev. a September