Runco XP-OPAL50, XP-OPAL65 operation manual IMSPC1

Page 72

Serial Communications

Table 6-1. Serial Commands (continued)

ASCII

 

 

Hex

Description

 

 

 

 

IMS:PC1

49

4D 53 3A 50 43 31

Input select = PC1 (Main Picture

 

 

 

 

when PIP mode)

 

 

 

 

IMS:SL1A

49

4D 53 3A 53 4C 31 41

Input select = SLOT1A (Main Pic-

 

 

 

 

ture when PIP mode)

 

 

 

 

IMS:SL1B

49

4D 53 3A 53 4C 31 42

Input select = SLOT1B (Main Pic-

 

 

 

 

ture when PIP mode)

 

 

 

 

IMS:SL2A

49

4D 53 3A 53 4C 32 41

Input select = SLOT2A (Main Pic-

 

 

 

 

ture when PIP mode)

 

 

 

 

IMS:SL2B

49

4D 53 3A 53 4C 32 42

Input select = SLOT2B (Main Pic-

 

 

 

 

ture when PIP mode)

 

 

 

 

IMS:SL3

49

4D 53 3A 53 4C 33

Input select = SLOT3 (Main Pic-

 

 

 

 

ture when PIP mode)

 

 

 

 

 

ISS:PC1

49

53 53 3A

50 43 31

Sub Picture Input Select = PC1

 

 

 

 

 

ISS:SL1A

49

53 53 3A

53 4C 31 41

Sub Picture Input Select =

 

 

 

 

SLOT1A

 

 

 

 

 

ISS:SL1B

49

53 53 3A

53 4C 31 42

Sub Picture Input Select =

 

 

 

 

SLOT1B

 

 

 

 

 

ISS:SL2A

49

53 53 3A

53 4C 32 41

Sub Picture Input Select =

 

 

 

 

SLOT2A

 

 

 

 

 

ISS:SL2B

49

53 53 3A

53 4C 32 42

Sub Picture Input Select =

 

 

 

 

SLOT2B

 

 

 

 

 

ISS:SL3

49

53 53 3A

53 4C 33

Sub Picture Input Select = SLOT3

 

 

 

 

 

OSP:OSD0

4F

53 50 3A

4F 53 44 30

OSD OFF

 

 

 

 

 

OSP:OSD1

4F

53 50 3A

4F 53 44 31

OSD ON

 

 

 

 

 

OSP:RCM0

4F

53 50 3A

52 43 4D 30

Remote Control User Level = Off

OSP:RCM1

4F

53 50 3A

52 43 4D 31

Remote Control User Level =

 

 

 

 

User1

OSP:RCM2

4F

53 50 3A

52 43 4D 32

Remote Control User Level =

 

 

 

 

User2

OSP:RCM3

4F

53 50 3A

52 43 4D 33

Remote Control User Level =

 

 

 

 

User3

 

 

 

 

 

OSP:SCR0

4F

53 50 3A

53 43 52 30

Screen Saver SCROLLING BAR

 

 

 

 

ONLY = OFF

 

 

 

 

 

OSP:SCR1

4F

53 50 3A

53 43 52 31

Screen Saver SCROLLING BAR

 

 

 

 

ONLY = ON

 

 

 

 

 

POF

50

4F 46

 

Power OFF

 

 

 

 

 

PON

50

4F 4E

 

Power ON

 

 

 

 

 

SSC:0000

53

53 43 3A

30 30 30 30

Screen Saver Duration = 0:00

 

 

 

 

(Interval Mode) or Finish Time =

 

 

 

 

0:00 (Time of Day Mode)

 

 

 

 

 

58

CinemaWall Installation/Operation Manual

Image 72
Contents XP-50 XP-65Page RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Maintenance and Troubleshooting SpecificationsAppendix A. Default Settings OperationList of Figures List of Figures Xiv Carriage return must be used after each command or string IntroductionAbout This Manual Target AudienceUsing This Manual Certain featuresSignificance. They also provide supplemental information Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-50 and XP-OPAL50 Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand Connectors XP-50 / XP-OPAL50 XP-65 / XP-OPAL65Power Input CinemaWall Remote Control Surround buttonControls and Functions Installation Remote ControlOther surfaces Quick Setup Installation must be performed by a qualified custom videoInstallation specialist Step Procedure For Details, refer toInstallation Considerations Ambient Light VentilationOther Considerations Connecting Source Connections toCinemaWall Components toDVD Analog RGB Connections Connecting External Speakers Optional Connector Pin AssignmentsRS-232 Controller ConnectionAC Power Connection Turning on the Power Changing the OSD Language Setting the Day and TimeOperation Setting the Computer Display Properties Selecting an Input Source Changing the Aspect Ratio Aspect ratio selection is saved independently for each input169 14943 431 linearly scales Source image horizonPlayed at the left and right Edges of the screenUsing Picture-In-Picture PIP Activating PIP Swapping the Main PIP ImagesUsing the On-Screen Menus Selecting a PIP TargetScreen or Input Source Changing the PIP Window PositionPOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness CinemaWall memorizes position and size settings separately POS./SIZEOptions menu refer to page 50 is set to On Frequency is 108 MHz or greaterOr 1080p and the Aspect Ratio is set to 169 refer to SoundSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Refer to Changing the OSD Language on Order to activate multi-display mode, you must first setOn hides joints between displays C D Transparency cannot be used when Insert is set to on Insert cannot be used when Transparency is set to onCommand Timer refer to Present Time Setup Refer to Setting the Day and Time onDVD3 Operation Return Change Refer toLevel see below Currently activeWhen using multiple displays such as in a video wall Runco Some cases, power is transmitted to the slot whenMULTI-DISPLAY is active Picture menu is set to WarmUsing Digital Zoom During the delay period, the power indicator flashes greenOn page 21, the Clock Display setting has no effect Operation Maintenance and Troubleshooting CleaningCleaning the Display Panel Body and Remote Control Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionCommand 3 bytes Parameter 3 bytes Command 3 bytes Parameter 6 bytesSerial Communications ExamplesSerial Commands Hex DescriptionDamzoom IMSPC1 SSCFNC0 VDO VWBGCT-30 Serial Communications Specifications CinemaWall SpecificationsCinemaWall Dimensions 12.31 Supported Timings Supported Signal Timings by Input Specifications Appendix A. Default Settings Table A-1. Runco Factory Default Settings for CinemaWallDefault Settings Page 020-0970-01 Rev. a September