Serial Communications

Table 6-1. Serial Commands (continued)

ASCII

 

Hex

 

Description

 

 

 

 

TIM:POF12359

54 49 4D 3A 50 4F 46 31 32 33

35 39

Power Off Time = 11:59PM

 

 

 

 

 

TIM:PON00000

54 49 4D 3A 50 4F

4E 30 30 30

30 30

Power On Time = None

 

 

 

 

 

TIM:PON10000

54 49 4D 3A 50 4F

4E 31 30 30

30 30

Power On Time = 0:00

 

 

 

 

 

TIM:PON12359

54 49 4D 3A 50 4F

4E 31 32 33

35 39

Power On Time = 11:59PM

 

 

 

 

 

 

VDO

56 44 4F

 

 

 

OSD clear

 

 

 

 

 

 

VMT

56 4D 54

 

 

 

Picture Mute (toggle)

 

 

 

 

 

VMT:0

56 4D 54 3A 30

 

 

Picture Mute = OFF

 

 

 

 

 

VMT:1

56 4D 54 3A 31

 

 

Picture Mute = ON

 

 

 

 

VPC:BLK030

56 50 43 3A

42 4C 4B 30 33 30

Brightness = 30 (max)

 

 

 

 

VPC:BLK-30

56 50 43 3A

42 4C 4B 2D 33 30

Brightness = -30 (min)

 

 

 

 

 

VPC:MENSTD

56 50 43 3A

4D 45 4E 53 54 44

 

Picture Menu = Standard

 

 

 

 

 

VPC:MENDYN

56 50 43 3A

4D 45 4E 44 59 4E

 

Picture Menu = ISF Day

 

 

 

 

VPC:MENCNM

56 50 43 3A

4D 45 4E 43 4E 4D

Picture Menu = ISF Night

 

 

 

 

VPC:MENMON

56 50 43 3A

4D 45 4E 4D 4F 4E

Picture Menu = Monitor

 

 

 

 

 

 

VPC:PAJ0

56 50 43 3A

50 41

4A 30

 

Color management = OFF

 

 

 

 

 

 

VPC:PAJ1

56 50 43 3A

50 41

4A 31

 

Color management = ON

 

 

 

 

 

VPC:PIC-30

56 50 43 3A

50 49 43 2D 33 30

 

Picture Level (Contrast) = -30

 

 

 

 

 

(min)

 

 

 

 

 

VPC:PIC000

56 50 43 3A

50 49 43 30 30 30

 

Picture Level (Contrast) = 0

 

 

 

 

 

VPC:PIC030

56 50 43 3A

50 49 43 30 33 30

 

Picture Level (Contrast) = 30

 

 

 

 

 

(max)

 

 

 

 

 

VPC:SHP015

56 50 43 3A

53 48 50 30 31 35

 

Sharpness = 15 (max)

 

 

 

 

 

VPC:SHP-15

56 50 43 3A

53 48 50 2D 31 35

 

Sharpness = -15 (min)

 

 

 

 

VPC:TMPCOL

56 50 43 3A

54 4D 50 43 4F 4C

Color Temp = COOL

 

 

 

 

VPC:TMPMID

56 50 43 3A

54 4D 50 4D 49 44

Color Temp = NORMAL

 

 

 

 

VPC:TMPWRM

56 50 43 3A

54 4D 50 57 52 4D

Color Temp = WARM

 

 

 

 

 

VWB:BCT030

56 57 42 3A

42 43 54 30 33 30

 

Blue Offset = 30 (max)

 

 

 

 

 

VWB:BCT-30

56 57 42 3A

42 43 54 2D 33 30

 

Blue Offset = -30 (min)

 

 

 

 

 

VWB:BDR030

56 57 42 3A

42 44 52 30 33 30

 

Blue Gain = 30 (max)

 

 

 

 

 

VWB:BDR-30

56 57 42 3A

42 44 52 2D 33 30

 

Blue Gain = -30 (min)

 

 

 

 

 

VWB:BEX000

56 57 42 3A

42 45 58 30 30 30

 

Black Extension = 0 (min)

 

 

 

 

 

VWB:BEX008

56 57 42 3A

42 45 58 30 30 38

 

Black Extension = 8 (max)

 

 

 

 

 

VWB:GCT030

56 57 42 3A

47 43 54 30 33 30

 

Green Offset = 30 (max)

 

 

 

 

 

 

60

CinemaWall Installation/Operation Manual

Image 74
Contents XP-50 XP-65Page RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents Appendix A. Default Settings Maintenance and TroubleshootingSpecifications OperationList of Figures List of Figures Xiv About This Manual Carriage return must be used after each command or stringIntroduction Target AudienceSignificance. They also provide supplemental information Using This ManualCertain features Degrade performance or cause a malfunctionDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-50 and XP-OPAL50 CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand Connectors XP-50 / XP-OPAL50 XP-65 / XP-OPAL65Power Input CinemaWall Remote Control Surround buttonControls and Functions Other surfaces InstallationRemote Control Installation specialist Quick SetupInstallation must be performed by a qualified custom video Step Procedure For Details, refer toInstallation Considerations Ambient Light VentilationOther Considerations CinemaWall Connecting SourceConnections to Components toDVD Analog RGB Connections RS-232 Controller Connecting External Speakers OptionalConnector Pin Assignments ConnectionAC Power Connection Operation Turning on the Power Changing the OSD LanguageSetting the Day and Time Setting the Computer Display Properties Selecting an Input Source Changing the Aspect Ratio Aspect ratio selection is saved independently for each input169 149Played at the left and right 43 431 linearly scalesSource image horizon Edges of the screenUsing Picture-In-Picture PIP Activating PIP Swapping the Main PIP ImagesScreen or Input Source Using the On-Screen MenusSelecting a PIP Target Changing the PIP Window PositionPOS./SIZE Options Picture This control is not available when Picture Menu is set to Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness CinemaWall memorizes position and size settings separately POS./SIZEOptions menu refer to page 50 is set to On Frequency is 108 MHz or greaterOr 1080p and the Aspect Ratio is set to 169 refer to SoundSET UP Signal Screensaver Is active On the remote control unit, or cycle power to the CinemaWall Refer to Changing the OSD Language on Order to activate multi-display mode, you must first setOn hides joints between displays C D Transparency cannot be used when Insert is set to on Insert cannot be used when Transparency is set to onCommand Timer refer to Present Time Setup Refer to Setting the Day and Time onDVD3 Operation Return Change Refer toLevel see below Currently activeMULTI-DISPLAY is active When using multiple displays such as in a video wall RuncoSome cases, power is transmitted to the slot when Picture menu is set to WarmOn page 21, the Clock Display setting has no effect Using Digital ZoomDuring the delay period, the power indicator flashes green Operation Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionSerial Communications Command 3 bytes Parameter 3 bytesCommand 3 bytes Parameter 6 bytes ExamplesSerial Commands Hex DescriptionDamzoom IMSPC1 SSCFNC0 VDO VWBGCT-30 Serial Communications Specifications CinemaWall SpecificationsCinemaWall Dimensions 12.31 Supported Timings Supported Signal Timings by Input Specifications Appendix A. Default Settings Table A-1. Runco Factory Default Settings for CinemaWallDefault Settings Page 020-0970-01 Rev. a September