Runco XP-50DHD, XP-50DHDxa, XP-65DHD, XP-65DHDxa, XP-103DHD manual Calibration

Page 56

Calibration

Calibration

ISF Night

Display Color

Input Image

Input Color

ISF Day

Display Color

Input Image

Input Color

Save ISF Settings

Output Shift

Splash Configure

OSD Position

Use the Calibration menu to perform advanced picture quality adjustments on the analog inputs. This menu should be used by ISF-certified technicians only.

To calibrate the digital (HDMI 1 and HDMI 2) inputs, use the Display

Note Image controls in the Service menu. For more information, refer to Display Device on page 48.

You must enter a passcode to access the Calibration menu.

Note

To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the ISF Presets menu (see above). Or, use the corresponding buttons on the remote control.

ISF Night - Display Color: Use the Display Color settings to adjust the color balance at the display device (as opposed to the DHD Controller) for analog sources (up to 1080i). These settings are saved independently for each input.

Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red or blue, decrease the Gain for that color.

Offset: Use the Offset controls in the White Balance sub-menu to correct color imbalances in the dark areas of the image. A good way to do this is to use a test pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red or blue, decrease the Offset for that color.

Gamma: The default gamma setting (1) is correct for almost all signals and conditions. If excess ambient light washes out the image and it becomes difficult or impossible to see details in dark areas, lower the gamma setting to compensate. This will improve contrast while maintaining good details for blacks. Conversely, if the image is washed out and unnatural, with excessive detail in black areas, increase the setting. Again, good gamma improves contrast while maintaining good details for blacks and whites.

Color Temp.: Select Color Temp from the Display Color menu to adjust the color temperature. For most situations, the appropriate setting is (1). The higher setting (2) produces a “bluer” picture; the lower one (0) a “warmer” picture with more pronounced red and orange hues.

AGC (Automatic Gain Control): AGC increases the brightness of dark signals automatically. To enable AGC, set it to 1 (on). To disable it, set it to 0 (off).

Input Level: The Input Level control allows you to adjust parts which are extremely bright and hard to see. (This cannot be adjusted when the input signal is digital.)

ISF Night - Input Image: The Input Image controls are similar to those in the Picture menu, but are accessible only by entering the Calibration menu passcode. This makes it possible to restore the picture quality settings to what they were when the display was installed, simply by recalling the “ISF Night” preset.

44

PlasmaWall XP Series Owner’s Operating Manual

Image 56
Contents XP-103DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Table of Contents Maintenance and Troubleshooting SpecificationsOperation Serial CommunicationsList of Figures List of Figures Xii Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-103DHD Optional Accessories XP-50DHD and XP-50DHDxaOptional Accessories XP-65DHD and XP-65DHDxa PlasmaWall at a Glance Controls and IndicatorsControls and Functions Display Stand Connectors PlasmaWall Rear PanelDHD Controller Front Panel Slot 1 Not used Slot 2 DVI-D or Dual Hdmi inputController to this input Slot 3 Not used PC in Not used RS-232C 9-pin, male D-SubEnter Button DHD Controller Rear Panel Outputs 1. Hdmi OUTComLink RS-232 Output RS-232 Control PortDHD Controller Remote Control DHD Controller Remote ControlOn / OFF Cursor KeysVideo Comp ComponentMemory Preset Buttons Aspect Ratio Selection Buttons16 9 Letbox LetterboxInstallation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toInstallation Considerations Ambient Light VentilationVentilation Requirements for Enclosure Mounting XP-103DHD Other Considerations PlasmaWall Rear Panel Connecting PlasmaWall to the DHD ControllerConnections to the PlasmaWall and DHD Controller Connecting the PlasmaWall DVI Version to the DHD Controller RS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source Components to the DHDHdmi Connections See Figure ControllerDigital DTV RGB Connections See Figure Digital DTV RGB ConnectionsAnalog Computer RGB Connections See Figure Personal ComputerComposite/S-Video/Component Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcConnecting 12-Volt RS-232 ControllerConnection Trigger Outputs toConnecting an External IR Receiver to the DHDConnecting AC Power 14. AC Power Connection15. Cable Management Turning on the Power Setting the Computer Display Properties OperationOperation Using the DHD Controller Menus Input Source Aspect RatioMemory Presets ServiceInput Source Aspect RatioMain Menu Input SourceAspect Ratio Aspect Ratio 169 Letterbox VirtualWide CinemaAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanMemory Presets InformationCalibration Operation Should be used by ISF-certified technicians only ServiceInput Names Restore Composite Video Component SD Exit PlasmaWall stores any changes you make to these settings HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Maintenance and Troubleshooting CleaningCleaning the Display Panel Body and Remote Control Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionPlasmaWall Maintenance and Troubleshooting Serial Communications Letterbox EnterInput Selection Commands CommandValue Description Min/max Stored? Power On/Off Commands Memory Preset Commands Iheight Miscellaneous Commands available on all inputs Hdinputres YESCommand Parameter min/max Value Stored? Description Enter keySpecifications PlasmaWall SpecificationsDHD Controller Specifications Dimensions PlasmaWall10.0 PlasmaWall Model XP-103DHD Dimensions with Floor Stand Specifications Page Runco CL-810 Owner’s Operating Manual