Use the controls in the Picture Menu to calibrate the analog inputs on the PlasmaWall for optimum picture quality.
To calibrate the digital (HDMI 1 and HDMI 2) inputs, use the Display
Note Image controls in the Service menu. For more information, refer to Display Device on page 48.
The PlasmaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted,
All signal types require separate processing. Therefore, you need to calibrate each DHD Controller input separately.
When you change a picture quality setting, save the change to a
Note preset afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for each input separately.) For information about saving settings, refer to Memory Presets on page 43.
Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results:
•External test pattern source – Ovation Multimedia, Video Essentials or AVIA test DVD (or equivalent).
•A blue filter (provided with many test DVDs), for color level and tint adjustments.
Connect your test pattern source to the input that you are calibrating and proceed as follows. Perform the adjustments in the order listed here.
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture
Picture
Picture
Brightness
Contrast
Color
Tint
Sharpness
Below Black
Above Black
Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness
PlasmaWall XP Series Owner’s Operating Manual | 39 |