Use the controls in the Picture Menu to calibrate the analog inputs on the PlasmaWall for optimum picture quality.

To calibrate the digital (HDMI 1 and HDMI 2) inputs, use the Display

Note Image controls in the Service menu. For more information, refer to Display Device on page 48.

The PlasmaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Runco video display devices. Accordingly, Runco recommends that setup and calibration be performed by an ISF-certified installation technician.

All signal types require separate processing. Therefore, you need to calibrate each DHD Controller input separately.

When you change a picture quality setting, save the change to a

Note preset afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for each input separately.) For information about saving settings, refer to Memory Presets on page 43.

Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results:

External test pattern source – Ovation Multimedia, Video Essentials or AVIA test DVD (or equivalent).

A blue filter (provided with many test DVDs), for color level and tint adjustments.

Connect your test pattern source to the input that you are calibrating and proceed as follows. Perform the adjustments in the order listed here.

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Picture

Picture

Brightness

Contrast

Color

Tint

Sharpness

Below Black

Above Black

Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

PlasmaWall XP Series Owner’s Operating Manual

39

Image 51
Contents XP-103DHD Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Table of Contents Serial Communications Maintenance and TroubleshootingSpecifications OperationList of Figures List of Figures Xii About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories XP-50DHD and XP-50DHDxa Optional Accessories XP-65DHD and XP-65DHDxaOptional Accessories XP-103DHD Controls and Indicators Controls and FunctionsPlasmaWall at a Glance Display Stand PlasmaWall Rear Panel ConnectorsSlot 3 Not used PC in Not used RS-232C 9-pin, male D-Sub DHD Controller Front PanelSlot 1 Not used Slot 2 DVI-D or Dual Hdmi input Controller to this inputEnter Button Outputs 1. Hdmi OUT DHD Controller Rear PanelRS-232 Control Port ComLink RS-232 OutputDHD Controller Remote Control DHD Controller Remote ControlComp Component On / OFFCursor Keys VideoLetbox Letterbox Memory Preset ButtonsAspect Ratio Selection Buttons 16 9Remote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupInstallation Considerations Ventilation Ambient LightVentilation Requirements for Enclosure Mounting XP-103DHD Other Considerations Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerPlasmaWall Rear Panel Connecting the PlasmaWall DVI Version to the DHD Controller RS-232 Connection from the DHD Controller to the PlasmaWall Controller Connecting SourceComponents to the DHD Hdmi Connections See FigureDigital DTV RGB Connections Digital DTV RGB Connections See FigurePersonal Computer Analog Computer RGB Connections See FigureDVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See FigureTrigger Outputs to Connecting 12-VoltRS-232 Controller ConnectionReceiver to the DHD Connecting an External IR14. AC Power Connection Connecting AC Power15. Cable Management Operation Turning on the Power Setting the Computer Display PropertiesOperation Input Source Aspect Ratio Using the DHD Controller MenusAspect Ratio Memory PresetsService Input SourceAspect Ratio 169 Letterbox VirtualWide Cinema Main MenuInput Source Aspect RatioRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Left/Right Up/Down Width Height Overscan Input PositionInformation Memory PresetsCalibration Operation Service Input Names Restore Composite Video Component SDShould be used by ISF-certified technicians only Exit PlasmaWall stores any changes you make to these settings HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsPlasmaWall Maintenance and Troubleshooting Letterbox Enter Serial CommunicationsCommand Value Description Min/max Stored? Power On/Off CommandsInput Selection Commands Memory Preset Commands Iheight Hdinputres YES Miscellaneous Commands available on all inputsEnter key Command Parameter min/max Value Stored? DescriptionPlasmaWall Specifications SpecificationsDHD Controller Specifications PlasmaWall Dimensions10.0 PlasmaWall Model XP-103DHD Dimensions with Floor Stand Specifications Page Runco CL-810 Owner’s Operating Manual