Runco XP-65DHD manual Value Description Min/max Stored? Power On/Off Commands

Page 68

Serial Communications

Table 6-1lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the DHD Controller ignores it and returns a minus sign (- >).

Table 6-1. Serial Commands

Command

Parameter

 

Value

Description

(min/max)

 

Stored?

 

 

 

 

 

 

 

 

 

 

Power On/Off Commands

 

 

 

 

 

OFF

NA

 

NA

Turns system off

 

 

 

 

 

ON

NA

 

NA

Turns system on

 

 

 

 

 

POWER

0/1

 

NA

Turns system on or off (toggles on/off state)

 

 

 

 

 

POWER?

NA

 

NA

Returns power status

 

 

 

 

 

Input Selection Commands

 

 

 

 

 

COMPONENT

NA

 

YES

Selects the Component input

 

 

 

 

 

COMPOSITE

NA

 

YES

Selects the Composite video input

 

 

 

 

 

HDMI1

NA

 

YES

Selects the HDMI 1 input

 

 

 

 

 

HDMI2

NA

 

YES

Selects the HDMI 2 input

 

 

 

 

 

HD1

NA

 

YES

Selects the RGB HD 1 input

 

 

 

 

 

HD2

NA

 

YES

Selects the RGB HD 2 input

 

 

 

 

 

INPUT?

NA

 

NA

Returns active input

 

 

 

 

 

SVIDEO1

NA

 

YES

Selects the S-Video 1 input

 

 

 

 

 

SVIDEO2

NA

 

YES

Selects the S-Video 2 input

 

 

 

 

Aspect Ratio Commands (not available on HDMI 1 or HDMI 2 inputs)

 

 

 

 

 

16:9

NA

 

YES

Selects the 16:9 aspect ratio

 

 

 

 

 

ASPECT?

NA

 

NA

Returns current aspect ratio

 

 

 

 

 

CINEMA

NA

 

YES

Selects the Cinema aspect ratio

 

 

 

 

 

LETTERBOX

NA

 

YES

Selects the Letterbox aspect ratio

 

 

 

 

 

4:3

NA

 

YES

Selects the 4:3 aspect ratio

 

 

 

 

 

VIRTUALWIDE

NA

 

YES

Selects the VirtualWide aspect ratio

 

 

 

 

 

56

PlasmaWall XP Series Owner’s Operating Manual

Image 68
Contents XP-103DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Table of Contents Maintenance and Troubleshooting SpecificationsOperation Serial CommunicationsList of Figures List of Figures Xii Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories XP-103DHD Optional Accessories XP-50DHD and XP-50DHDxaOptional Accessories XP-65DHD and XP-65DHDxa PlasmaWall at a Glance Controls and IndicatorsControls and Functions Display Stand Connectors PlasmaWall Rear PanelDHD Controller Front Panel Slot 1 Not used Slot 2 DVI-D or Dual Hdmi inputController to this input Slot 3 Not used PC in Not used RS-232C 9-pin, male D-SubEnter Button DHD Controller Rear Panel Outputs 1. Hdmi OUTComLink RS-232 Output RS-232 Control PortDHD Controller Remote Control DHD Controller Remote ControlOn / OFF Cursor KeysVideo Comp ComponentMemory Preset Buttons Aspect Ratio Selection Buttons16 9 Letbox LetterboxInstallation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toInstallation Considerations Ambient Light VentilationVentilation Requirements for Enclosure Mounting XP-103DHD Other Considerations PlasmaWall Rear Panel Connecting PlasmaWall to the DHD ControllerConnections to the PlasmaWall and DHD Controller Connecting the PlasmaWall DVI Version to the DHD Controller RS-232 Connection from the DHD Controller to the PlasmaWall Connecting Source Components to the DHDHdmi Connections See Figure ControllerDigital DTV RGB Connections See Figure Digital DTV RGB ConnectionsAnalog Computer RGB Connections See Figure Personal ComputerComposite/S-Video/Component Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcConnecting 12-Volt RS-232 ControllerConnection Trigger Outputs toConnecting an External IR Receiver to the DHDConnecting AC Power 14. AC Power Connection15. Cable Management Turning on the Power Setting the Computer Display Properties OperationOperation Using the DHD Controller Menus Input Source Aspect RatioMemory Presets ServiceInput Source Aspect RatioMain Menu Input SourceAspect Ratio Aspect Ratio 169 Letterbox VirtualWide CinemaAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanMemory Presets InformationCalibration Operation Should be used by ISF-certified technicians only ServiceInput Names Restore Composite Video Component SD Exit PlasmaWall stores any changes you make to these settings HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Maintenance and Troubleshooting CleaningCleaning the Display Panel Body and Remote Control Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionPlasmaWall Maintenance and Troubleshooting Serial Communications Letterbox EnterInput Selection Commands CommandValue Description Min/max Stored? Power On/Off Commands Memory Preset Commands Iheight Miscellaneous Commands available on all inputs Hdinputres YESCommand Parameter min/max Value Stored? Description Enter keySpecifications PlasmaWall SpecificationsDHD Controller Specifications Dimensions PlasmaWall10.0 PlasmaWall Model XP-103DHD Dimensions with Floor Stand Specifications Page Runco CL-810 Owner’s Operating Manual