Installation
Configure Lens Motor Trigger: CineWide with AutoScope maintains constant image height independent of the aspect ratio, while using the full display resolution of the projector. It accomplishes this by moving the anamorphic lens in front of the primary lens when widescreen material is being viewed. When the viewer transitions back to 16:9 or 4:3 source material, the anamorphic lens moves out of the light path.
To configure the lens motor trigger on the DHD Controller for proper AutoScope operation:
1.Project a 2.35:1 aspect ratio test pattern or other image on the screen.
2.On the DHD Controller remote control or front panel, press MENU.
3.Select Service from the Main Menu and enter the Service Menu passcode.
Note | You must enter a passcode to access the Service menu for the first |
time after turning on the system. |
4.Select Triggers from the Service menu.
5.Assign the trigger output to which the lens motor is connected to the Cinema and Virtual Cinema aspect ratios. This enables the lens motor to move the anamorphic lens into position (in front of the primary lens) when either aspect ratio is selected.
6.Select the Cinema aspect ratio to move the anamorphic lens into position, if it isn’t already. To do this, press CINEMA on the DHD Controller remote control (Figure
Adjusting the Horizontal (X) Lens Position:
1.Project a white field on the screen.
2.Loosen the
3.Slowly move the anamorphic lens into place (from right to left or vice versa) so that there are no shadows on either side of the screen:
Too Far Left
Correct position
Too Far Right
4.When the horizontal position is properly set, tighten the
Runco | 43 |