Panasonic AW-RP50N Setting the User buttons, Registering functions User buttons

Page 16

Setting the USER buttons

Menu items can be assigned to the two USER buttons (USER1, USER2).

The target function can be activated simply by pressing the USER button (USER1 or USER2).

 

F1

 

 

F2

 

POWER ALARM

F1

CAMERA

 

 

OSD

 

 

1

2

3

4

5

 

 

MENU

PAGE

GAIN/PED

R/B GAIN

R/B PED

AWB/ABB

SHUTTER

F2

EXIT

 

 

6

7

8

9

10

 

 

STORE

DELETE

DETAIL

SCENE/MODE

CAMERA

SETUP

SYSTEM

USER1

USER2

 

 

 

PRESET MEMORY / MENU

 

 

 

Menu item

Details of operation performed

 

 

 

SWLINK

This sets the link control

On: Enable

 

between the unit and switcher.

Off: Disable

 

 

 

BUSCONT

This is the bus switching

On: Enable

 

setting.

Off: Disable

 

 

 

FASIST

This sets the focus assist

On: Enable

 

function.

Off: Disable

 

 

 

CAMSEL

This displays icons at the

 

 

bottom left of the images from

On: Display

 

the remote camera selected

 

Off: Non-display

 

by the unit on the multi view

 

 

 

display of the switcher.

 

 

 

 

TALLY_IP

This sends the tally information

 

 

sent periodically by UDP from

On: Enable

 

the switcher to the remote

Off: Disable

 

camera.

 

 

 

 

CAMINF

This sends the camera

 

 

information of the remote

On: Enable

 

camera selected to the

Off: Disable

 

switcher.

 

 

 

 

AWB

AWB is executed when the USER button, in which

 

AWB has been assigned, is pressed.

 

When AWB is executed successfully, the indicator

 

of the button goes off; conversely, when it is not

 

executed successfully, it blinks.

 

 

 

ABB

ABB is executed when the USER button, in which

 

ABB has been assigned, is pressed.

 

When ABB is executed successfully, the indicator

 

of the button goes off; conversely, when it is not

 

executed successfully, it blinks.

 

 

 

POWER OFF

When the USER button in which POWER OFF

 

has been assigned is held down, the indicator of

 

the button lights for an instant, and power OFF is

 

requested for all the remote cameras connected.

 

 

 

Registering functions in the

USER buttons

1 Set the MENU button to ON.

Press the MENU button to light its indicator.

2 Set the PRESET MEMORY/MENU 9 button (SETUP) to ON.

When the button is pressed and its indicator lights, the [SETUP] menu is displayed on the LCD panel.

 

[1]USER

3

Press the F1 dial.

 

4

Turn the F1 dial to display [USER1] or [USER2].

 

1.USER1

 

 

SWLINK

5 Turn the F2 dial to select the item to be assigned, and press the F2 dial.

1.USER1 ▼

SWLINK

Turn the F2 dial, and then press it.

1.USER1 ▼

BUSCONT

16

Image 16
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on and off How to turn the power of the remote cameras onHow to turn the power of the remote cameras off CAM Power Group OFFTurn the F2 dial to select OFF, and press Turn the F2 dial to select ALL OFF, and press the F2 dialSetting and operating the preset memories Preset numbers and registered pagesPreset number Number  Memo Executing the preset data Deleting the preset memory dataPRESET1 PAGE1Setting the gain Selecting the settings for a selected remote cameraSetting the pedestal Setting the white balance Set the Preset MEMORY/MENU 4 button AWB/ABB to onTurn the F1 dial to select the white balance mode Selecting the white balance modeTurn the F2 dial to select AWB, and press Automatically adjusting the white balanceAWB MOD AWB a SET AWB Set the Preset MEMORY/MENU 2 button R/BGAIN to on Turn the F1 dial to select ATWRgain BgainSet the Preset MEMORY/MENU 3 button R/BPED to on Setting the black balanceTurn the F2 dial to select ABB, and press Setting the shutter speed Setting the detailSet the Preset MEMORY/MENU 5 button Shutter to on Turn the F1 dial to select the shutter modeSetting the shooting mode Set the Preset MEMORY/MENU 7 button SCENE/MODE to onTurn the F1 dial to select the shooting mode Specifying the color barsTable of operations Operating the menu items of the selected remote cameraRemote camera Menu ON/OFF Dial operation Menu operation Set the Preset MEMORY/MENU 9 button Setup to on Setting the User buttonsRegistering functions User buttons Tally settings 3TALLYTally OUT OffSetting the functions Turn the F1 dial to select the target menu itemZoom DIR Normal Setting the remote camera operationsFocus DIR Normal Setting the PAN/TILT lever inclination and speed Selecting the control items pan, tilt, zoom and focusFOCUS/IRIS Standard Speed TargetScope Mode a Mode Operations performedReturning the remote cameras to their home position Diag SpeedSetting the upper limit Setting the lower limitWhen the AW-HE50 is used When any other remote camera is usedSetting the left limit Setting the right limit6FUNCTION Exercising external control over the preset memory data Adjusting the minimum lens zoom start speedPreset CTL1 Adjusting the LCD panel backlight Menu Control EnableLocking the button operations 9LCD BLSetting linkup with the switcher Switcher network settingsSet Preset MEMORY/MENU 10 button System to on Press the Exit buttonLink setting 2SW LinkSwlink Off Swlink OnTurn the F1 dial to select the input line of the switcher Setting the image output and image input4SW Assign Switcher settings Buscont Off Bus switchingTurn the F1 dial to select the menu item to be set Buscont OffCamsel Off BUS AUXFasist Off T Lever Tallyip OffSelf Setting for the information to be displayed on the OSD Setting all the information displaysTogether Turn the F1 dial to and select the menu item to be setSetting each information item to be displayed Checking the equipment alarm information Select Power10ALARM Select CAM1 to CAM100Press the F2 dial to initialize the settings Turn the F2 dial to select the initializing modeReturning the unit to its factory status Control interface for external devices Sub 15-pin, female, inch threadExample of GPI OUT connections Current Max mA AW-RP50Installing the software Setup SoftwareIP settings Displaying the Setting tab Auto IP setting Changing the IP addressesChanging the camera numbers Initializing the IP addressesLoading the setting files Saving the setting filesSaving and loading data Saving the log filesReferencing the network environment Enter the IP addresses in the AW-RP50 IP Address boxesButton Menu item Control device Initial value Setting Table of menu items0dB to 12dB 1 step AW-HE50Video Buscont Option AW-HE50 Display only F0610Y1070 D
Related manuals
Manual 82 pages 17 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.