Displaying the “Setting” tab

List box

The IP address of the AW-RP50 connected to the network is displayed here.

The information of the network environment established by the AW-RP50 selected here is displayed on the “Setting” tab.

Type

The units connected to the selected AW-RP50 are displayed in this column.

CAMERA: Remote camera

SW: Switcher

Group

The numbers of the groups of cameras controlled by the selected AW-RP50 are displayed in this column.

CAMERA No

The numbers of the cameras controlled by the selected AW-RP50 are displayed in this column.

Type

The connection methods used for the units connected to the selected AW-RP50 are displayed in this column.

Serial: Serial connection

Network: IP connection

NoAsign: No setting (default setting)

The connection method can be changed manually. Click on the right, and select “Serial,” “Network” or “NoAsign”.

“Serial” can be selected only with Group 1.

After the method has been changed, click the [SET] button to reflect the change.

CAMERA Name

The names of the cameras set in the remote cameras are displayed in this column.

They are displayed for the remote cameras in the currently selected group.

For remote cameras with a serial connection, they are displayed only when the cameras are selected by the unit.

SW Input

The input connectors of the switcher are displayed in this column.

The input connector can be changed manually.

Click on the right, and select “NoAsign” or an input connector from “INPUT1” to “INPUT5.”

After the connector has been changed, click the [SET] button to reflect the change.

MAC Address

The MAC addresses of the remote cameras and switcher connected to the selected AW-RP50 are displayed in this column.

IP Address

The IP addresses of the remote cameras and switcher connected to the selected AW-RP50 are displayed in this column.

The IP addresses can be changed by inputting them directly. After inputting an IP address, click the [SET] button to reflect the change.

HTTP Port

The numbers of the ports used to connect the selected AW-RP50 are displayed in this column.

CAMERA Select

The numbers of the cameras to be changed are displayed in this column.

The numbers of the cameras can be changed manually. Click on the right, and select a number from “C001” to “C100.”

After the camera number has been changed, click the [SET] button to reflect the change.

Alarm

The alarm information of the remote cameras is displayed in this column.

They are displayed for the remote cameras in the currently selected group.

For remote cameras with a serial connection, they are displayed only when the cameras are selected.

39

Image 39
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on How to turn the power of the remote cameras on and offTurn the F2 dial to select ALL OFF, and press the F2 dial How to turn the power of the remote cameras offCAM Power Group OFF Turn the F2 dial to select OFF, and press Memo  Setting and operating the preset memoriesPreset numbers and registered pages Preset number NumberPAGE1 Executing the preset dataDeleting the preset memory data PRESET1Selecting the settings for a selected remote camera Setting the gainSetting the pedestal Selecting the white balance mode Setting the white balanceSet the Preset MEMORY/MENU 4 button AWB/ABB to on Turn the F1 dial to select the white balance modeAutomatically adjusting the white balance Turn the F2 dial to select AWB, and pressAWB MOD AWB a SET AWB Bgain Set the Preset MEMORY/MENU 2 button R/BGAIN to onTurn the F1 dial to select ATW RgainSetting the black balance Set the Preset MEMORY/MENU 3 button R/BPED to onTurn the F2 dial to select ABB, and press Turn the F1 dial to select the shutter mode Setting the shutter speedSetting the detail Set the Preset MEMORY/MENU 5 button Shutter to onSpecifying the color bars Setting the shooting modeSet the Preset MEMORY/MENU 7 button SCENE/MODE to on Turn the F1 dial to select the shooting modeOperating the menu items of the selected remote camera Table of operationsRemote camera Menu ON/OFF Dial operation Menu operation Setting the User buttons Set the Preset MEMORY/MENU 9 button Setup to onRegistering functions User buttons Off Tally settings3TALLY Tally OUTTurn the F1 dial to select the target menu item Setting the functionsSetting the remote camera operations Zoom DIR NormalFocus DIR Normal Speed Target Setting the PAN/TILT lever inclination and speedSelecting the control items pan, tilt, zoom and focus FOCUS/IRIS StandardDiag Speed Scope Mode aMode Operations performed Returning the remote cameras to their home positionWhen any other remote camera is used Setting the upper limitSetting the lower limit When the AW-HE50 is usedSetting the right limit Setting the left limit6FUNCTION Adjusting the minimum lens zoom start speed Exercising external control over the preset memory dataPreset CTL1 9LCD BL Adjusting the LCD panel backlightMenu Control Enable Locking the button operationsPress the Exit button Setting linkup with the switcherSwitcher network settings Set Preset MEMORY/MENU 10 button System to onSwlink On Link setting2SW Link Swlink OffSetting the image output and image input Turn the F1 dial to select the input line of the switcher4SW Assign Buscont Off Switcher settingsBuscont Off Bus switching Turn the F1 dial to select the menu item to be setBUS AUX Camsel OffFasist Off Tallyip Off T LeverSelf Turn the F1 dial to and select the menu item to be set Setting for the information to be displayed on the OSDSetting all the information displays TogetherSetting each information item to be displayed Select CAM1 to CAM100 Checking the equipment alarm informationSelect Power 10ALARMTurn the F2 dial to select the initializing mode Press the F2 dial to initialize the settingsReturning the unit to its factory status Current Max mA AW-RP50 Control interface for external devicesSub 15-pin, female, inch thread Example of GPI OUT connectionsSetup Software Installing the softwareIP settings Displaying the Setting tab Initializing the IP addresses Auto IP settingChanging the IP addresses Changing the camera numbersSaving the log files Loading the setting filesSaving the setting files Saving and loading dataEnter the IP addresses in the AW-RP50 IP Address boxes Referencing the network environmentAW-HE50 Button Menu item Control device Initial value SettingTable of menu items 0dB to 12dB 1 stepVideo Buscont Option AW-HE50 Display only F0610Y1070 D
Related manuals
Manual 82 pages 17 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.