Panasonic AW-RP50N operating instructions Setting the image output and image input, 4SW Assign

Page 29

Setting the functions when the unit is linked with the switcher

Set the various functions to be used when the unit is linked with the switcher.

Setting the image output and image input

This setting establishes the correlation between the image output (remote camera) and image input (switcher).

By establishing the setting, the switcher is notified if a remote camera which has been set is selected when the remote cameras have been selected by the unit.

1 Set the MENU button to ON.

Press the MENU button to light its indicator.

2 Set PRESET MEMORY/MENU 10 button (SYSTEM) to ON.

When the button is pressed and its indicator is lighted, the [SYSTEM] menu is displayed on the LCD panel.

[1]CAMERA CTL ▼

3 Turn the F1 dial, display the SW ASSIGN menu, and press the F1 dial.

[4]SW ASSIGN

Press the F1 dial.

1.INPUT1 ▼ CAM1

4 Turn the F1 dial to select the input line of the switcher.

1.INPUT1 ▼ CAM1

Turn the F1 dial.

2.INPUT2 CAM1

5 Turn the F2 dial, select the remote camera, and then press the F2 dial to enter the selection.

2.INPUT2 CAM1

Turn the F2 dial, and then press it.

2.INPUT2 CAM2

The switcher has five input lines: INPUT1 to INPUT5.

Take the above steps to set the remote cameras for the input lines, and then operate the remote cameras.

 Select “NoAsign” if the switcher is not to be notified of the correlation setting when the remote cameras have been selected.

29

Image 29
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on How to turn the power of the remote cameras on and offCAM Power Group OFF How to turn the power of the remote cameras offTurn the F2 dial to select OFF, and press Turn the F2 dial to select ALL OFF, and press the F2 dialPreset numbers and registered pages Setting and operating the preset memoriesPreset number Number  Memo Deleting the preset memory data Executing the preset dataPRESET1 PAGE1Setting the pedestal Selecting the settings for a selected remote cameraSetting the gain Set the Preset MEMORY/MENU 4 button AWB/ABB to on Setting the white balanceTurn the F1 dial to select the white balance mode Selecting the white balance modeAWB MOD AWB a SET AWB Automatically adjusting the white balanceTurn the F2 dial to select AWB, and press Turn the F1 dial to select ATW Set the Preset MEMORY/MENU 2 button R/BGAIN to onRgain BgainTurn the F2 dial to select ABB, and press Setting the black balanceSet the Preset MEMORY/MENU 3 button R/BPED to on Setting the detail Setting the shutter speedSet the Preset MEMORY/MENU 5 button Shutter to on Turn the F1 dial to select the shutter modeSet the Preset MEMORY/MENU 7 button SCENE/MODE to on Setting the shooting modeTurn the F1 dial to select the shooting mode Specifying the color barsRemote camera Menu ON/OFF Dial operation Menu operation Operating the menu items of the selected remote cameraTable of operations Registering functions User buttons Setting the User buttonsSet the Preset MEMORY/MENU 9 button Setup to on 3TALLY Tally settingsTally OUT OffTurn the F1 dial to select the target menu item Setting the functionsFocus DIR Normal Setting the remote camera operationsZoom DIR Normal Selecting the control items pan, tilt, zoom and focus Setting the PAN/TILT lever inclination and speedFOCUS/IRIS Standard Speed TargetMode Operations performed Scope Mode aReturning the remote cameras to their home position Diag SpeedSetting the lower limit Setting the upper limitWhen the AW-HE50 is used When any other remote camera is usedSetting the right limit Setting the left limit6FUNCTION Preset CTL1 Adjusting the minimum lens zoom start speedExercising external control over the preset memory data Menu Control Enable Adjusting the LCD panel backlightLocking the button operations 9LCD BLSwitcher network settings Setting linkup with the switcherSet Preset MEMORY/MENU 10 button System to on Press the Exit button2SW Link Link settingSwlink Off Swlink On4SW Assign Setting the image output and image inputTurn the F1 dial to select the input line of the switcher Buscont Off Bus switching Switcher settingsTurn the F1 dial to select the menu item to be set Buscont OffFasist Off BUS AUXCamsel Off Self Tallyip OffT Lever Setting all the information displays Setting for the information to be displayed on the OSDTogether Turn the F1 dial to and select the menu item to be setSetting each information item to be displayed Select Power Checking the equipment alarm information10ALARM Select CAM1 to CAM100Returning the unit to its factory status Turn the F2 dial to select the initializing modePress the F2 dial to initialize the settings Sub 15-pin, female, inch thread Control interface for external devicesExample of GPI OUT connections Current Max mA AW-RP50IP settings Setup SoftwareInstalling the software Displaying the Setting tab Changing the IP addresses Auto IP settingChanging the camera numbers Initializing the IP addressesSaving the setting files Loading the setting filesSaving and loading data Saving the log filesEnter the IP addresses in the AW-RP50 IP Address boxes Referencing the network environmentTable of menu items Button Menu item Control device Initial value Setting0dB to 12dB 1 step AW-HE50Video Buscont Option AW-HE50 Display only F0610Y1070 D
Related manuals
Manual 82 pages 17 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.