Panasonic AW-RP50N Switcher settings, Turn the F1 dial to select the menu item to be set

Page 30
Press the MENU button to light its indicator.

Setting the functions when the unit is linked with the switcher

Switcher settings

A setting for controlling the switcher linked with the unit is available.

It is established using the [SETUP] menu.

Before taking the steps described here, the steps for “Switcher network settings” and “Setting the image output and image input” must be taken.

First, the basic menu operations will be described.

5 Turn the F2 dial, select the settings, and then press the F2 dial to change the setting.

2.BUSCONT Off

Turn the F2 dial, and then press it.

2.BUSCONT On

1 Set the MENU button to ON.

2 Set PRESET MEMORY/MENU 9 button (SETUP) to ON.

When the button is pressed and its indicator is lighted, the [SETUP] menu is displayed on the LCD panel.

[1]USER ▼

3 Turn the F1 dial, display the SW LINK menu, and press the F1 dial.

[2]SW LINK

Press the F1 dial.

1.SWLINK ▼ Off

4 Turn the F1 dial to select the menu item to be set.

1.SWLINK ▼ Off

Turn the F1 dial.

2.BUSCONT Off

Bus switching

From the [SETUP] menu, select [SW LINK] and display [BUSCONT]. Then select On or Off.

2.BUSCONT On

When “On” is selected as the item setting, the materials set using the BUS item (described later) are sent from the remote camera to the switcher when the remote cameras has been selected using one of the unit’s CAMERA STATUS/SELECTION buttons.

Control can also be exercised by assigning this setting to a USER button.

30

Image 30
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on and off How to turn the power of the remote cameras onTurn the F2 dial to select OFF, and press How to turn the power of the remote cameras offCAM Power Group OFF Turn the F2 dial to select ALL OFF, and press the F2 dialPreset number Number Setting and operating the preset memoriesPreset numbers and registered pages  Memo PRESET1 Executing the preset dataDeleting the preset memory data PAGE1Selecting the settings for a selected remote camera Setting the gainSetting the pedestal Turn the F1 dial to select the white balance mode Setting the white balanceSet the Preset MEMORY/MENU 4 button AWB/ABB to on Selecting the white balance modeAutomatically adjusting the white balance Turn the F2 dial to select AWB, and pressAWB MOD AWB a SET AWB Rgain Set the Preset MEMORY/MENU 2 button R/BGAIN to onTurn the F1 dial to select ATW BgainSetting the black balance Set the Preset MEMORY/MENU 3 button R/BPED to onTurn the F2 dial to select ABB, and press Set the Preset MEMORY/MENU 5 button Shutter to on Setting the shutter speedSetting the detail Turn the F1 dial to select the shutter modeTurn the F1 dial to select the shooting mode Setting the shooting modeSet the Preset MEMORY/MENU 7 button SCENE/MODE to on Specifying the color barsOperating the menu items of the selected remote camera Table of operationsRemote camera Menu ON/OFF Dial operation Menu operation Setting the User buttons Set the Preset MEMORY/MENU 9 button Setup to onRegistering functions User buttons Tally OUT Tally settings3TALLY OffSetting the functions Turn the F1 dial to select the target menu itemSetting the remote camera operations Zoom DIR NormalFocus DIR Normal FOCUS/IRIS Standard Setting the PAN/TILT lever inclination and speedSelecting the control items pan, tilt, zoom and focus Speed TargetReturning the remote cameras to their home position Scope Mode aMode Operations performed Diag SpeedWhen the AW-HE50 is used Setting the upper limitSetting the lower limit When any other remote camera is usedSetting the left limit Setting the right limit6FUNCTION Adjusting the minimum lens zoom start speed Exercising external control over the preset memory dataPreset CTL1 Locking the button operations Adjusting the LCD panel backlightMenu Control Enable 9LCD BLSet Preset MEMORY/MENU 10 button System to on Setting linkup with the switcherSwitcher network settings Press the Exit buttonSwlink Off Link setting2SW Link Swlink OnSetting the image output and image input Turn the F1 dial to select the input line of the switcher4SW Assign Turn the F1 dial to select the menu item to be set Switcher settingsBuscont Off Bus switching Buscont OffBUS AUX Camsel OffFasist Off Tallyip Off T LeverSelf Together Setting for the information to be displayed on the OSDSetting all the information displays Turn the F1 dial to and select the menu item to be setSetting each information item to be displayed 10ALARM Checking the equipment alarm informationSelect Power Select CAM1 to CAM100Turn the F2 dial to select the initializing mode Press the F2 dial to initialize the settingsReturning the unit to its factory status Example of GPI OUT connections Control interface for external devicesSub 15-pin, female, inch thread Current Max mA AW-RP50Setup Software Installing the softwareIP settings Displaying the Setting tab Changing the camera numbers Auto IP settingChanging the IP addresses Initializing the IP addressesSaving and loading data Loading the setting filesSaving the setting files Saving the log filesReferencing the network environment Enter the IP addresses in the AW-RP50 IP Address boxes0dB to 12dB 1 step Button Menu item Control device Initial value SettingTable of menu items AW-HE50Video Buscont Option AW-HE50 Display only F0610Y1070 D
Related manuals
Manual 82 pages 17 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.