Hach 900 MAX manual Appendix A

Models: 900 MAX

1 160
Download 160 pages 21.13 Kb
Page 110
Image 110
Manual background

Appendix A

Sigma 900 MAX Refrigerated Sampler Advanced Sampling Flow Chart

Main Menu

Display Data

Options

Setup

Status

Modify

 

An arrow displayed next to an Advanced Sampling

 

Select Only One Channel or

Selected

option in the menu display signifies it is enabled.

 

 

 

 

 

 

 

External Control for Setpoint.

Items

Advanced

 

 

 

 

 

 

 

 

 

Sampling

Program

Enable /

 

Level

 

 

 

 

 

 

Complete

 

 

Set HIGH

 

 

 

 

Disable

 

Flow

 

 

 

 

 

Output

 

pH / ORP

trigger and

 

 

 

 

 

 

Deadband

Enter Delay

Note: Enables pin F for

 

 

Start on

Process Temp

Program Complete output on

 

 

Channel 1

 

When Input

 

 

Setpoint

or

Auxillary connector.

Setpoint *

Enable /

Channel 2

 

Becomes

Also disables its use for

-or-

Channel 3

Set LOW

 

Active

Bottle# & Full Bottle Indicator.

Sampling

Disable

Start /

Ch4 or D.O.

trigger and

 

 

 

 

 

 

Stop on

Ch5 or D.O. Temp

Deadband

 

 

 

 

 

 

Ch6 or Cond

 

 

 

 

 

 

Setpoint

 

 

 

 

 

 

 

Ch7 or Cond Temp

 

 

 

 

 

 

 

 

Flow Rate of Chg

Set High

 

Set

 

 

 

 

 

 

Time

 

 

 

 

 

Rainfall

Trigger

 

 

 

 

 

 

Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

External Control

 

 

 

Note: The Special Output

Special

Enable /

Enable: After Each Sample, Only When

 

 

signal is available on pin E of

 

 

the Auxiliary connector.

Output

Disable

Pumping or From Rinse to Purge

 

 

 

 

Start /

Enable /

Time / Date

 

Begin with

Enter Time and Date for

 

 

Disable

or

 

Bottle 1 on

each start and stop

 

 

Stop

 

 

 

 

each New

 

 

 

 

 

 

 

 

Enter Time and Day of

 

 

Times

 

Time / Weekday

 

 

 

Start?

 

 

 

Week for each start and stop

 

 

 

 

 

 

 

 

 

 

Select Start

 

 

 

 

 

 

 

 

 

* Note: Setpoint Sampling &

 

 

Condition: Rain,

Select

Select:

 

Enter

Storm Water Cannot

Storm

Enable /

Level, Rain AND

# of

 

Sampling

Samples/Bottle

Be Enabled at the Same

Water

Disable

Level, Rain OR

First

Interval

 

Time.

or

 

 

 

 

 

Level, Immediate

Flush

 

 

 

 

 

 

or

 

Bottles/Sample

Enter

 

 

 

 

 

Bottles

 

 

 

 

External Trigger

 

 

 

Sample

Note: Timed Bottle is not

Timed

 

Clock

Enter Time of next

 

 

Volume

allowed unless Bottles-per-

Enable /

Enable/

 

 

Bottle

Time

 

Bottle Set

 

 

Sample mode is selected in

Disable

 

Disable

 

 

Distribution Menu.

Sets

or

 

 

 

Enter

 

 

 

Continuous

 

 

 

 

 

Enter Time Interval

Program

 

 

 

 

Duration

Mode

 

 

 

 

 

till next Bottle Set

 

Time Limit

 

 

 

 

 

 

 

 

 

 

 

Level

 

Set HIGH

 

 

Select:

 

 

Upset

Enable /

Flow

 

 

 

 

 

pH / ORP

 

Trigger

Enter #

Samples/Bottle

 

 

Sample

Disable

Process Temp

 

or

of

 

 

 

 

or

 

 

 

 

Channel 1

 

Upset

 

 

 

 

 

 

 

Bottles/Sample

 

 

 

 

Channel 2

 

Set LOW

Bottles

 

 

 

 

Channel 3

 

Trigger

 

 

 

 

 

Variable

Enable /

Ch 4 or D.O.

 

 

 

 

 

 

 

Ch 5 or DO Temp.

 

 

 

 

 

 

 

Intervals

Disable

 

 

 

 

 

 

 

Ch 6 or Cond.

 

 

 

Enter Sample

 

 

 

 

Ch 7 or Cond Tmp

 

 

 

 

 

 

 

 

 

Volume

 

 

 

 

 

 

 

 

 

key:

Set

 

 

 

 

 

Set

 

Set

 

 

Flow Rate of Chg

 

 

HIGH

 

Time

 

 

Sample

 

 

Rainfall

 

 

 

Grey box indicates function not available with

 

 

 

 

 

Trigger

 

Interval

 

Intervals

 

 

 

 

 

 

CTVV sampling enabled. [Even if function is

 

 

 

External Control

 

 

 

 

 

still listed in screen menus.]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 108

Quick Start Guides

8990apdx_quickstart.fm

Page 110
Image 110
Hach 900 MAX manual Appendix A