Panasonic BT-LH2550P, BT-LH2550E manual Gpi, GPI Control, Disable, Enable, GPI1 GPI8

Page 35

Main Menu (continued)

GPI

“GPI CONTROL” is used to enable and disable GPI functions and assign functions to each of the GPI terminal pins ( page 48).

 

 

Underlined values indicate factory defaults.

 

 

 

Sub menu

Settings

Description

 

 

 

GPI CONTROL

DISABLE

Enables and disables GPI functions

 

ENABLE

<DISABLE> Disabled

 

 

<ENABLE> Enabled

 

 

 

GPI1 - GPI8

UNDEF

Assigns functions to the GPI control terminal pins.

 

MARKER1 ON/OFF

The same items can be set to each terminal ( page

 

MARKER2 ON/OFF

48).

 

MARKER BACK

 

 

HALF

 

 

MARKER BACK

 

 

BLACK

 

 

CENTER MARKER

 

 

INPUT SEL. VIDEO

 

 

INPUT SEL. SDI1

 

 

INPUT SEL. SDI2

 

 

INPUT SEL.

 

 

YPBPR/RGB

 

 

INPUT SEL. DVI-D

 

 

SD ASPECT

 

 

SCAN

 

 

R-TALLY

 

 

G-TALLY

 

 

MONO

 

 

GAMMA SEL. FILM

 

 

GAMMA SEL.

 

 

STDIO/PST

 

 

SELECT SYNC

 

 

 

 

Note:

This function is not available when,

“SD ASPECT” operation when input signal is HD or PC

“SCAN” operation when the input signal is PC

“GAMMA SELECT” operation when the input signal is PC

“SELECT SYNC” operation when anything other than “RGB-VIDEO” is selected under “YPBPR/RGB” in the “INPUT SELECT” menu

“MONO” operation when input signal is PC

35

Image 35
Contents BT-LH2550P BT-LH2550E This Equipment Must be Grounded Read this first ! for BT-LH2550PDeclaration of Conformity Read this first ! for BT-LH2550PDo not Remove Panel Covers by Unscrewing Them Read this first ! for BT-LH2550EThis Equipment Must be Earthed Operating precaution Transportation precautionsApparatus is compliant with Read this firstOptional units Precautions for UseContents Standard accessoriesOutline AC Adaptor DimensionsVideo monitor unit Front view Rear view Tally lamp page 35 Front panel controls Power switchPower LED Controls and Their FunctionsMenu button Adjust buttonFront panel controls Input buttonRear panel terminals AC in AC inlet Power switch on , OFFPower lamp AC AdapterConnecting the power cord Power SupplySharpness display How to Use the On Screen MenuInput signal status Picture/volume adjusting menuMenu display Function displayAudio level meter display Closed Caption CC display Time Code display TCEnter Menu operationsBright Light Backlight Volume Picture/volume adjusting menu operationsPhase Chroma Saving user data Loading user data User DataMain Menu Menu configurationBACK*2 Sub menu Setting DescriptionMarker MarkerCross Hatch GPI PRESET1*5GPI PRESET2*5 Marker TYPE*4*6Center marker Marker typesVista marker, Cnsco marker Area markerMain Menu Video Config SCAN*2 MONO*2ANAMO*2*8 SD ASPECT*2Gain Green ResetColor TEMP.*1 Gain REDSystem Config RXD TXD DTR DSR GND RTS CTS Equipment required for calibrationCALIBRATION*1 Performing Auto Calibration Reset operationRESET*2 AutoFunction FunctionSD Aspect HV DelayAuto Setup Gamma SelectAudio Level Meter AutosetupBlue only SUB Input SELGPI Control DisableEnable GPIInput Select WXGA/XGA AUTOSETUP*1Phase ClockAudio Display Setup Normal screen TWO Window function 1920 1280 640 960 TWO Window sizeMain window HD and sub-window SD DVI-COMP NtscPAL Hourmeter ControlList of setting restrictions available, × not available Chroma Bright Operating conditions Remote SpecificationsGPI terminal RS-232C terminal RS-232C remote control methodSetting command Command Description Data Response This command returns the sub-window setting Query commandError Display Maintenance inspecionsMaintenance Specifications SDI1 SDI2 YP BP R SpecifictionsMemo Panasonic Canada Inc