NEC NF2300-SE41E manual

Page 23

(2)SERVICE LED (orange)

The SERVICE LED goes on orange if an error occurs in the additional disk enclosure.

The LED is off while the disk enclosure operates normally.

(3)Disk drive/dummy tray

Disk drive:

Contains a hard disk drive (HDD) with the dedicated tray.

Dummy tray:

Contains only the dedicated tray with no hard disk drive.

*The additional disk enclosure NF2300-SE41E is not equipped with disk drives at the shipment. To use the additional disk enclosure, add disk drives sold separately.

*The disk drives installed in the disk enclosure are dedicated to the FC loop at 2Gbps.

A mixture of 1Gbps and 2Gbps disk drives is not permitted. Do not install any 1Gbps disk drives in the disk enclosure.

The following measures are adopted to prevent insertion of a 1Gbps disk drive:

A)A 1Gbps disk drive cannot go into the position where a 2Gbps disk drive is locked.

B)The ejector color is different.

(4)HDD READY LED (green)

The HDD READY LED is lit green while the disk drive operates normally. The LED blinks when the disk drive transfers data.

The HDD READY LED blinks during the self-test or initialization just after power-on.

(5)HDD FAULT LED (orange)

The HDD FAULT LED goes on at the occurrence of an error in the disk drive. The LED is off while the disk drive operates normally.

(6)Ejector

The ejector is used to install or remove the disk drive or dummy tray. In the normal operation status, the ejectors fix disk drives or dummy tray to the additional disk enclosure.

When inserting the disk drive into the disk enclosure, push it as far as it will go and then lock the ejector.

Incorrect insertion may cause malfunction.

- 9 -

Image 23
Contents NF2300-SE41E Additional Disk Enclosure Users Guide Page Safety Precautions Page Iii Indication on Safety Page Trademarks Preface Check of Components in Package NF2300-SE41E This Users Guide also uses the following symbol Contents Action Taken AT Occurrence of Fault or Error Page Environment in Use of Additional Disk Enclosure Installation and Connection of Additional Disk Enclosure Page Page Routine Inspection of Additional Disk Enclosure Features of Additional Disk Enclosure Disk Enclosure Front Names and Roles of SectionsPage Disk Enclosure Rear Power Supply for Disk Enclosure Page Diag Ready LED AdapterPage Installation and Connection Procedures Installation and Connection ProceduresConnection of Additional Disk Enclosure Page Connection of Additional Disk Enclosure OFF Page Page 2 1 on When DE-DIAG ID = 0 When DE-DIAG ID = Sample configuration 1 NF2300-SR4xxE Sample configuration 2 NF2300-SR4xxE + NF2300-SP02E Connection of Power Cords Page Addition of Disk Drive Addition of Optional DevicesInstallation procedure Page Page Location 00 in NF2300-SE41E Handling of Additional Disk Enclosure Power On/Off of Additional Disk Enclosure Power switches of disk enclosures Page Page Page Switches of array controller are turned off Spare Disk Setting Procedure LD Logical Disk Setting ProcedureAction Taken AT Occurrence of Fault or Error Additional Disk Enclosure Connection of Additional Disk Indication at Occurrence of Fault Fault of Disk Drive Location label Page Fault of Power Supply for Disk Enclosure Page Page Page Be careful that it is hot Fault of AdapterPage Page Check of Type Name and Manufacturing Numbers Disposal of Additional Disk Enclosure Service and SupportUnit Life/Repair Service Period Preparation before Phone CallEnvironmental Conditions of Additional Disk Enclosure Product SpecificationBasic Specification of Additional Disk Enclosure Optional ComponentsExternal Dimension and Weight of Additional Disk Enclosure Power Specification