NEC NF2300-SE41E manual Indication at Occurrence of Fault

Page 57

8.2Indication at Occurrence of Fault

If the additional disk enclosure is defected, the SERVICE LED goes on orange and also the LED specific for each unit to indicate that the unit is defected goes on.

The table below shows the relation between the LED indicating the occurrence of a fault and the defected unit.

LED display

Defected unit

The SERVICE LED on the disk enclosure is lit

The disk drive with the FAULT LED being on

orange and also the FAULT LED on the disk

is defected.

drive is lit orange.

 

The SERVICE LED on the disk enclosure is lit

The adapter with the FAULT LED being on is

orange and also the FAULT LED on the adapter

defected.

is lit orange.

 

The SERVICE LED on the disk enclosure is lit

The power supply for the disk enclosure with

orange and also the POWER FAULT LED on

POWER FAULT LED being on is defected

the power supply for the disk enclosure is lit

(including cooling fan for power supply

orange.

failure).

- 43 -

Image 57
Contents NF2300-SE41E Additional Disk Enclosure Users Guide Page Safety Precautions Page Iii Indication on Safety Page Trademarks Preface Check of Components in Package NF2300-SE41E This Users Guide also uses the following symbol Contents Action Taken AT Occurrence of Fault or Error Page Environment in Use of Additional Disk Enclosure Installation and Connection of Additional Disk Enclosure Page Page Routine Inspection of Additional Disk Enclosure Features of Additional Disk Enclosure Disk Enclosure Front Names and Roles of SectionsPage Disk Enclosure Rear Power Supply for Disk Enclosure Page Diag Ready LED AdapterPage Installation and Connection Procedures Installation and Connection ProceduresConnection of Additional Disk Enclosure Page Connection of Additional Disk Enclosure OFF Page Page 2 1 on When DE-DIAG ID = 0 When DE-DIAG ID = Sample configuration 1 NF2300-SR4xxE Sample configuration 2 NF2300-SR4xxE + NF2300-SP02E Connection of Power Cords Page Addition of Disk Drive Addition of Optional DevicesInstallation procedure Page Page Location 00 in NF2300-SE41E Handling of Additional Disk Enclosure Power On/Off of Additional Disk Enclosure Power switches of disk enclosures Page Page Page Switches of array controller are turned off Spare Disk Setting Procedure LD Logical Disk Setting ProcedureAction Taken AT Occurrence of Fault or Error Additional Disk Enclosure Connection of Additional Disk Indication at Occurrence of Fault Fault of Disk Drive Location label Page Fault of Power Supply for Disk Enclosure Page Page Page Be careful that it is hot Fault of AdapterPage Page Check of Type Name and Manufacturing Numbers Unit Life/Repair Service Period Service and SupportPreparation before Phone Call Disposal of Additional Disk EnclosureBasic Specification of Additional Disk Enclosure Product SpecificationOptional Components Environmental Conditions of Additional Disk EnclosureExternal Dimension and Weight of Additional Disk Enclosure Power Specification