NEC NF2300-SE41E manual

Page 49

(2)Notes on turning off AC power

The disk array unit to be connected with the additional disk enclosure periodically writes data from the cache memory onto a disk. If you turn off the AC power before completion of write to the disk, the remaining data on the disk is backed up by the battery backup units.

However, the backup time is limited (4 days if the cache memory has the allowable maximum capacity and the two battery backup units are fully charged). To securely protect data, turn off the AC power after all the data has been written from the cache memory in the disk array unit onto the disk. Turn off the AC power according to the procedure explained in "(3) Turning off AC power".

1.Turn off the host system and the host bus adapter or the FC-AL switch. Alternatively, offline all the buses connected to the host system that is connected with the disk array unit.

2.If NEC Storage DynamicDataReplication is used, execute the Unpair command.

3.Turn on the shut down switch (toggle switch with SHUT DOWN indicated) of the LAN card in the array controller. (*1)

4.Confirm that [SDN LED] of the LAN card in the array controller is on, and then turn off the AC power according to the procedure explained in "(3) Turning off AC power".

[SDN LED] flashes while data remaining in cache memory is being written onto the disk drive. Do not turn off the AC power while it is flashing. (*2)

Relationship between [SDN LED] states and operations of the disk array unit:

Normal state:

Off

During cache data write onto disk:

Flashing

Completion of cache data write onto disk: On

Writing cache data onto a disk drive usually takes about 10 minutes and 20 minutes at maximum.

If cache data is not written onto a disk drive normally, the LEDs of the LAN card enters the following states. In this case, contact your maintenance service agent.

RDY LED: On

FLT LED: Flashing

SDN LED: Off

5.Turn off the shut down switch (toggle switch with SHUT DOWN indicated) of the LAN card in the array controller. (*3)

- 35 -

Image 49
Contents NF2300-SE41E Additional Disk Enclosure Users Guide Page Safety Precautions Page Iii Indication on Safety Page Trademarks Preface Check of Components in Package NF2300-SE41E This Users Guide also uses the following symbol Contents Action Taken AT Occurrence of Fault or Error Page Environment in Use of Additional Disk Enclosure Installation and Connection of Additional Disk Enclosure Page Page Routine Inspection of Additional Disk Enclosure Features of Additional Disk Enclosure Disk Enclosure Front Names and Roles of SectionsPage Disk Enclosure Rear Power Supply for Disk Enclosure Page Diag Ready LED AdapterPage Installation and Connection Procedures Installation and Connection ProceduresConnection of Additional Disk Enclosure Page Connection of Additional Disk Enclosure OFF Page Page 2 1 on When DE-DIAG ID = 0 When DE-DIAG ID = Sample configuration 1 NF2300-SR4xxE Sample configuration 2 NF2300-SR4xxE + NF2300-SP02E Connection of Power Cords Page Addition of Disk Drive Addition of Optional DevicesInstallation procedure Page Page Location 00 in NF2300-SE41E Handling of Additional Disk Enclosure Power On/Off of Additional Disk Enclosure Power switches of disk enclosures Page Page Page Switches of array controller are turned off Spare Disk Setting Procedure LD Logical Disk Setting ProcedureAction Taken AT Occurrence of Fault or Error Additional Disk Enclosure Connection of Additional Disk Indication at Occurrence of Fault Fault of Disk Drive Location label Page Fault of Power Supply for Disk Enclosure Page Page Page Be careful that it is hot Fault of AdapterPage Page Check of Type Name and Manufacturing Numbers Unit Life/Repair Service Period Service and SupportPreparation before Phone Call Disposal of Additional Disk EnclosureBasic Specification of Additional Disk Enclosure Product SpecificationOptional Components Environmental Conditions of Additional Disk EnclosureExternal Dimension and Weight of Additional Disk Enclosure Power Specification