8.4Fault of Power Supply for Disk Enclosure
If the power supply for the additional disk enclosure is defected, the SERVICE LED on the array controller is lit orange. In addition, the SERVICE LED on the additional disk enclosure in which the defected power supply is installed and the POWER FAULT LED on the defected power supply are lit orange.
The defected power supply for the disk enclosure may be replaced with the powers of the array controller and additional disk enclosure remaining ON.
When replacing a power supply for the disk enclosure, prepare the new power supply before removing the old one, and then replace it within about 3 minutes.
The following are heating units of the disk enclosure:
A)Disk drives
B)Power supplies for the disk enclosure
The fans in the power supplies for the disk enclosure serve as cooling fans for both of the above. Therefore, do not leave the disk enclosure with one of the power supplies removed. Doing so causes the disk drive temperature to rise, which may significantly decrease the reliability.
<Replacement procedure>
(1)Turn off the power switch of the defected power supply for the disk enclosure. Push down the power cord stopper (for the power cord) toward the left, release the power cord stopper from the receptacle of the power cord, and then remove the power cord.
ON | OFF |
- 47 -