Sharp PN-V602 Turning Power On/Off, 17 E, Turning on the main power, Turning power on/off

Page 17

Turning Power On/Off

Caution

Turn on the monitor first before turning on the PC or playback device.

Turning on the main power

Main power switch

TIPS

If the monitor is in the input signal standby mode and you press the POWER button on the remote control unit, the monitor enters standby mode.

Setting the SCHEDULE flashes the power LED alternately in red and orange in standby mode.

To disable the logo screen from displaying when turning the power ON, set LOGO SCREEN to OFF on the SETUP menu. (See page 25.)

If you change the remote control mode to ALL MONITORS, power can be turned ON/OFF for all secondary monitors connected with RS-232 cable. (For operation with the monitor buttons, use the buttons on the primary monitor.)

Caution

The main power must be turned on/off with the main power switch. Do not connect/disconnect the power cord or turn the breaker on/off while the main power switch is on.

When switching the main power switch or the POWER button off and back on, always wait for at least 5 seconds.

For a complete electrical disconnection, pull out the main plug.

Turning power on/off

Press the POWER button on the remote control unit or the monitor itself to turn the power ON/OFF.

When the main power switch is off, the monitor cannot be turned on using the POWER button on the remote control unit.

Power LED Power button

Status of a power LED

Status of the monitor

Green lighting

Power on

 

 

Orange lighting

Power off (Standby mode)

 

 

Green flashing

Input signal waiting mode

Caution

When switching the main power switch or the POWER button off and back on, always wait for at least 5 seconds.

A short interval may result in a malfunction.

nDate/time setting

If the time has yet to be set when the monitor is first turned on, the date/time setting screen appears. Set the date and time.

DATE/TIME SETTING

 

 

 

/

/

:

:

 

 

 

 

 

 

SET

 

01 / 01 / 20 11

12

: 00 AM

 

 

 

 

 

 

CANCEL

 

 

 

 

OK···[MENU]

1.Press , , or to select the date and

time, and press or to change the numerical values.

2.Press or to select SET and then press MENU .

Be sure to set the date and time.

The date/time setting screen will close automatically if no operation is performed for about 15 seconds. The date and time can be set using DATE/TIME SETTING from the

OPTION menu when the date/time setting screen disappears.

TIPS

Set the date in “Month/Day/Year” order.

Set the time on a 12-hour basis.

The clock is maintained by the internal battery.

If you already set the time but the date/time setting screen appears when the power is turned on, the internal battery may be exhausted. Please contact your local Sharp servicing dealer or service center for assistance with battery replacement.

Estimated service life of the internal battery: About 5 years (depending on monitor operation)

The initial battery was inserted at the factory when the monitor was shipped, so it may run out of power before its expected operation life.

Disabling power on/off operations

Power on/power off operations can be disabled in order to protect the monitor from an accidental power off. Set the ADJUSTMENT LOCK in FUNCTION menu to “ON 2”. (See page 31.)

17 E

Image 17
Contents PN-V602 GREEN-AND-YELLOW For Customers in U.KBlue BrownImportant Information Refer Servicing to Qualified Service PersonnelInformation on Disposal for Business Users Information on Disposal for Users private householdsEuropean Union Other Countries outside the EUDear Sharp Customer Safety Precautions Fan in this product has a limited lifetime Use only the power cord supplied with the monitorRear side buttons Remote control unit buttons Mounting Precautions Supplied Components ContentsNRear view Part NamesNFront view 11 E Connection when the PN-ZB02 optional is attached Connecting Peripheral Equipment13 E Connecting Peripheral EquipmentMultiple monitor connection Connection with video cableSet the ID No Connection with the control kit optionalConnect the monitors in order Connecting the Power Cord Preparing the Remote Control UnitInstalling the batteries Remote control operation rangeRemoving the Handles Binding CablesAffixing the Protection Covers Be sure the handles are attached securelyTurning on the main power Turning Power On/OffTurning power on/off Disabling power on/off operationsVOL +/- Volume adjustment Input Input mode selectionBasic Operation MuteDisplay 19 EBasic Operation Wide Zoom Normal Basic Operation NSwitching the screen sizeDot by Dot Cut off21 E Remote Control ModeThis Monitor only Specified MonitorDisplaying the menu screen Menu ItemsNExample of operation NMenu screen displayMenu item details 23 ENSCREEN Menu Items NPICTURENAUDIO NSETUPMenu Items 25 E Menu Items NOPTION Menu Items NPIP/PbyP 27 ENMULTI PIP Menu Items NDual screen displayNEnlarge NSCHEDULE NZOOM2 Special Setting29 E NScreen display for adjustment Adjustments for PC screen displayNAutomatic adjustment 31 E Controlling the Monitor with a PC RS-232C Communication procedurePC connection Communication conditionsNCommunication interval 33 EControlling the Monitor with a PC RS-232C NCommands for ID controlNID numbers Advanced operationNRepeater control 35 EVOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←NTo transfer the Gamma user data Setting of the Gamma user dataNSaving the Gamma user data NActivating the Gamma user dataPower control/Input mode selection RS-232C command tableHow to read the command table 37 EControlling the Monitor with a PC RS-232C Screen menu Controlling the Monitor with a PC RS-232C Picture menu 39 EControlling the Monitor with a PC RS-232C Audio menu Setup menuControlling the Monitor with a PC RS-232C Option menu 41 EHorizontal orientation Vertical orientation Image Position Epos settingControlling the Monitor with a PC RS-232C Multi menu Controlling the Monitor with a PC RS-232C PIP/PbyP menu Initialization/Functional Restriction Setting Function menu43 E Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataControlling the Monitor with a PC LAN Settings to connect to a LAN45 E To set on the monitorControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.0Controlling the Monitor with a PC LAN 47 EControlling with a PC Information about this monitor appears Standby mode, Power on is the operation available49 E User Name / PasswordDNS Server Accept IP AddressAuthentication Installation Information NAME/LOCATIONAccount Name / Password Monitor NameRecipient E-MAIL Addresses 51 ECondition ConfirmationTrap Setting Snmp SettingTrap Setting of Authentication Error Version53 E TroubleshootingTroubleshooting NPN-V602 Product Specifications SpecificationsNPN-ZR01 optional Product Specifications 55 ENPower management Specifications NDimensional DrawingsNPOWER Limited See Set to ensure maximum power consumption. See57 E Specifications NCompatible signal timing PCSpecifications NCompatible signal timing AV 59 E PN-V602 Mu EN11H1
Related manuals
Manual 28 pages 8.65 Kb Manual 60 pages 10.1 Kb