nMULTI

ENLARGE (See page 28.)

Sets whether or not to use the enlarge function.

ADVANCED (ENLARGE)

ENLARGE H / ENLARGE V

.......... Sets the number of screen splits (number of

monitors) in the horizontal/vertical direction used for the enlargement.

ENLARGE-POS

.......... Specify the split screen to be displayed when the

enlargement function is used. H-POS / V-POS

.......... Adjust the horizontal/vertical position of the enlarged

screen.

BEZEL ADJUST

Sets whether or not to use the frame correction function.

ADVANCED (BEZEL ADJUST)

BEZEL ADJUST (TOP) / BEZEL ADJUST (BOTTOM) / BEZEL ADJUST (RIGHT) / BEZEL ADJUST (LEFT)

.......... Adjusts so that the top/bottom/left/right connecting

joints of grouped units will be displayed smoothly when a group of monitors are aligned in multiples to display a single image.

BEZEL (TOP) / BEZEL (BOTTOM) / BEZEL (RIGHT) /

BEZEL (LEFT)

.......... Sets the frame width of the display.

Menu Items

nPIP/PbyP

PIP MODES

Sets the display method.

OFF

Displays one screen.

PIP

Displays a sub screen inside a main screen.

PbyP

Displays a main screen and a sub screen in a line.

PbyP2

Displays a main screen which measures 1024 pixels

 

in the longest direction and a sub screen in a line.

PIP SIZE

Sets the size of the sub screen in PIP mode.

PIP H-POS

Adjusts the horizontal position of the sub screen in PIP mode.

PIP V-POS

Adjusts the vertical position of the sub screen in PIP mode.

PIP BLEND

In PIP mode, use this menu item to display the sub screen transparently.

PIP SOURCE

Selects the input signal of the sub screen in PIP, PbyP, or PbyP2 mode.

SOUND CHANGE

Sets the sound which is output in PIP, PbyP, or PbyP2 mode. If the main screen is displayed as a full screen by the AUTO OFF function, the sound for the main screen is output even when the sound for the sub screen is specified.

MAIN POS

Sets the position of the main screen in PbyP or PbyP2 mode.

PbyP2 POS

Sets the position of the sub screen in PbyP2 mode.

AUTO OFF

Sets the display method when no signals for the sub screen are input in PIP, PbyP, or PbyP2 mode.

MANUAL....... Displays a main screen and a black sub screen.

AUTO............ Displays the main screen as a full screen.

TIPS

When WHITE BALANCE is set to THRU, BLACK LEVEL, CONTRAST, TINT, COLORS, RGB INPUT RANGE, GAMMA, and COPY TO USER cannot be set.

If COLOR MODE is set to sRGB, the following items cannot be set.

WHITE BALANCE, PRESET, USER, COPY TO USER, and

GAMMA

When the COLOR MODE is set to VIVID or HIGH ILLUMINANCE, GAMMA can not be adjusted.

STANDBY MODE cannot be set to LOW POWER when SCHEDULE is effective or when OFF is selected for LED in

FUNCTION.

When displaying the color pattern, it is possible to adjust certain items of the PICTURE menu.

Non-adjustable items cannot be selected.

Audio input from the HDMI input terminal is also not output.

27 E

Image 27
Contents PN-V602 Brown For Customers in U.KGREEN-AND-YELLOW BlueImportant Information Refer Servicing to Qualified Service PersonnelOther Countries outside the EU Information on Disposal for Users private householdsInformation on Disposal for Business Users European UnionDear Sharp Customer Safety Precautions Use only the power cord supplied with the monitor Rear side buttons Remote control unit buttonsFan in this product has a limited lifetime Mounting Precautions Supplied Components ContentsPart Names NFront viewNRear view 11 E Connection when the PN-ZB02 optional is attached Connecting Peripheral EquipmentConnection with video cable Connecting Peripheral Equipment13 E Multiple monitor connectionConnection with the control kit optional Connect the monitors in orderSet the ID No Remote control operation range Preparing the Remote Control UnitConnecting the Power Cord Installing the batteriesBe sure the handles are attached securely Binding CablesRemoving the Handles Affixing the Protection CoversDisabling power on/off operations Turning Power On/OffTurning on the main power Turning power on/offMute Input Input mode selectionVOL +/- Volume adjustment Basic Operation19 E Basic OperationDisplay Cut off Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotSpecified Monitor Remote Control Mode21 E This Monitor onlyNMenu screen display Menu ItemsDisplaying the menu screen NExample of operationMenu Items NPICTURE 23 EMenu item details NSCREENNSETUP Menu ItemsNAUDIO 25 E Menu Items NOPTION 27 E NMULTIMenu Items NPIP/PbyP Menu Items NDual screen display NEnlargePIP NZOOM2 Special Setting 29 ENSCHEDULE Adjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment 31 E Communication conditions Communication procedureControlling the Monitor with a PC RS-232C PC connectionNCommunication interval 33 EAdvanced operation NCommands for ID controlControlling the Monitor with a PC RS-232C NID numbersOK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ← 35 ENRepeater control VOLM0020 ←NActivating the Gamma user data Setting of the Gamma user dataNTo transfer the Gamma user data NSaving the Gamma user data37 E RS-232C command tablePower control/Input mode selection How to read the command tableControlling the Monitor with a PC RS-232C Screen menu Controlling the Monitor with a PC RS-232C Picture menu 39 EControlling the Monitor with a PC RS-232C Audio menu Setup menuControlling the Monitor with a PC RS-232C Option menu 41 EImage Position Epos setting Controlling the Monitor with a PC RS-232C Multi menuHorizontal orientation Vertical orientation Initialization/Functional Restriction Setting Function menu 43 EControlling the Monitor with a PC RS-232C PIP/PbyP menu Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataTo set on the monitor Settings to connect to a LANControlling the Monitor with a PC LAN 45 EControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.047 E Controlling with a PCControlling the Monitor with a PC LAN Information about this monitor appears Standby mode, Power on is the operation availableAccept IP Address User Name / Password49 E DNS ServerMonitor Name Installation Information NAME/LOCATIONAuthentication Account Name / PasswordConfirmation 51 ERecipient E-MAIL Addresses ConditionVersion Snmp SettingTrap Setting Trap Setting of Authentication Error53 E TroubleshootingTroubleshooting 55 E SpecificationsNPN-V602 Product Specifications NPN-ZR01 optional Product SpecificationsSet to ensure maximum power consumption. See Specifications NDimensional DrawingsNPower management NPOWER Limited See57 E Specifications NCompatible signal timing PCSpecifications NCompatible signal timing AV 59 E PN-V602 Mu EN11H1