Sharp PN-V602 Important Information, Refer Servicing to Qualified Service Personnel

Page 3

IMPORTANT INFORMATION

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

CAUTION

RISK OF ELECTRIC

SHOCK

DO NOT OPEN

CAUTION:  TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within a triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

WARNING:

FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment.

NOTE:

This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This product utilizes a CR coin Lithium battery which contains a Perchlorate material.

Special handling for this material may apply,

California residents, See www.dtsc.ca.gov/hazardouswaste/perchlorate/

Others, consult local environmental officers.

U.S.A. ONLY

3 E

Image 3
Contents PN-V602 Brown For Customers in U.KGREEN-AND-YELLOW BlueImportant Information Refer Servicing to Qualified Service PersonnelOther Countries outside the EU Information on Disposal for Users private householdsInformation on Disposal for Business Users European UnionDear Sharp Customer Safety Precautions Use only the power cord supplied with the monitor Rear side buttons Remote control unit buttonsFan in this product has a limited lifetime Mounting Precautions Supplied Components ContentsPart Names NFront viewNRear view 11 E Connection when the PN-ZB02 optional is attached Connecting Peripheral EquipmentConnection with video cable Connecting Peripheral Equipment13 E Multiple monitor connectionConnection with the control kit optional Connect the monitors in orderSet the ID No Remote control operation range Preparing the Remote Control UnitConnecting the Power Cord Installing the batteriesBe sure the handles are attached securely Binding CablesRemoving the Handles Affixing the Protection CoversDisabling power on/off operations Turning Power On/OffTurning on the main power Turning power on/offMute Input Input mode selectionVOL +/- Volume adjustment Basic Operation19 E Basic OperationDisplay Cut off Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotSpecified Monitor Remote Control Mode21 E This Monitor onlyNMenu screen display Menu ItemsDisplaying the menu screen NExample of operationMenu Items NPICTURE 23 EMenu item details NSCREENNSETUP Menu ItemsNAUDIO 25 E Menu Items NOPTION 27 E NMULTIMenu Items NPIP/PbyP Menu Items NDual screen display NEnlargePIP NZOOM2 Special Setting 29 ENSCHEDULE Adjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment 31 E Communication conditions Communication procedureControlling the Monitor with a PC RS-232C PC connectionNCommunication interval 33 EAdvanced operation NCommands for ID controlControlling the Monitor with a PC RS-232C NID numbersOK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ← 35 ENRepeater control VOLM0020 ←NActivating the Gamma user data Setting of the Gamma user dataNTo transfer the Gamma user data NSaving the Gamma user data37 E RS-232C command tablePower control/Input mode selection How to read the command tableControlling the Monitor with a PC RS-232C Screen menu Controlling the Monitor with a PC RS-232C Picture menu 39 EControlling the Monitor with a PC RS-232C Audio menu Setup menuControlling the Monitor with a PC RS-232C Option menu 41 EImage Position Epos setting Controlling the Monitor with a PC RS-232C Multi menuHorizontal orientation Vertical orientation Initialization/Functional Restriction Setting Function menu 43 EControlling the Monitor with a PC RS-232C PIP/PbyP menu Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataTo set on the monitor Settings to connect to a LANControlling the Monitor with a PC LAN 45 EControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.047 E Controlling with a PCControlling the Monitor with a PC LAN Information about this monitor appears Standby mode, Power on is the operation availableAccept IP Address User Name / Password49 E DNS ServerMonitor Name Installation Information NAME/LOCATIONAuthentication Account Name / PasswordConfirmation 51 ERecipient E-MAIL Addresses ConditionVersion Snmp SettingTrap Setting Trap Setting of Authentication Error53 E TroubleshootingTroubleshooting 55 E SpecificationsNPN-V602 Product Specifications NPN-ZR01 optional Product SpecificationsSet to ensure maximum power consumption. See Specifications NDimensional DrawingsNPower management NPOWER Limited See57 E Specifications NCompatible signal timing PCSpecifications NCompatible signal timing AV 59 E PN-V602 Mu EN11H1