Sharp PN-V602 operation manual Menu Items NDual screen display, NEnlarge, Pip

Page 28

Menu Items

nDual screen display

You can display the screens of the PC input signal and AV input signal simultaneously.

Set this function with “PIP MODES” in the PIP/PbyP menu.

PIP

 

 

 

 

 

 

 

 

A sub screen is displayed

 

 

 

 

 

 

 

 

 

 

Main screen

 

 

 

 

inside a main screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub

 

 

 

 

 

 

 

 

screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PbyP

 

 

 

 

 

 

 

 

A main screen and a sub

 

 

 

 

 

 

 

 

 

 

Main

 

 

 

Sub

 

screen are displayed in a

 

 

 

 

 

line.

 

 

screen

 

screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PbyP2

 

 

 

 

 

 

 

 

Displays a main screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which measures 1024

 

 

 

 

 

 

Sub

 

 

 

Main screen

 

 

pixels in the longest

 

 

 

screen

 

 

 

 

 

 

 

 

 

 

direction and a sub

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screen in a line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The currently selected input signal is displayed on the main screen.

*You cannot simultaneously display the screens of signals of the same type, such as two types of PC input signals or two types of AV input signals.

*The dual screen display cannot be used with the combination of PC DVI-D and AV HDMI or of AV DVI-D and

PC HDMI.

TIPS

You might infringe on a copyright of the author which is protected by copyright law when you display the images of the computer screen and television/VCR simultaneously for profit-making or to show the image to the public.

The screen size for dual-screen display is the same as the screen size for single-screen display. The Dot by Dot screen is displayed in NORMAL size except when it is set as the PIP main screen.

When dual-screen display is selected, the SCREEN

MOTION function is disabled.

When dual-screen display is selected, the AUTO INPUT CHANGE function is disabled.

When dual-screen display is selected, the screen cannot be enlarged.

When dual-screen display is selected, the INPUT SELECT options cannot be set.

When an interlaced signal (1080i, 480i, video, S-Video) is input to the sub screen, horizontal lines may flicker. If this happens, display the image on the main screen.

nEnlarge

You can align several monitors and integrate them into a single large screen to display.

Up to five monitors can be aligned in both the horizontal and vertical directions.

Each monitor displays enlarged views of separated images.

(Example)

Horizontal direction: 2 monitors

Vertical direction: 2 monitors

Horizontal direction: 3 monitors

Vertical direction: 2 monitors

Setting procedure

Set using the MULTI menu.

1.Set ENLARGE to ON.

2.Select ADVANCED (ENLARGE).

3.Set the number of monitors aligned in the horizontal direction in ENLARGE H.

4.Set the number of monitors aligned in the vertical direction in ENLARGE V.

5.Set the section of the separated image to be displayed on each monitor in ENLARGE-POS.

1)Press .

2)Press , , or to select position, then press MENU .

TIPS

When Enlarge is used, the SCREEN MOTION function is disabled.

When Enlarge is used, the AUTO INPUT CHANGE function is disabled.

When Enlarge is used, the HDMI AUTO VIEW function is disabled.

E28

Image 28
Contents PN-V602 For Customers in U.K GREEN-AND-YELLOWBlue BrownRefer Servicing to Qualified Service Personnel Important InformationInformation on Disposal for Users private households Information on Disposal for Business UsersEuropean Union Other Countries outside the EUDear Sharp Customer Safety Precautions Rear side buttons Remote control unit buttons Use only the power cord supplied with the monitorFan in this product has a limited lifetime Mounting Precautions Contents Supplied ComponentsNFront view Part NamesNRear view 11 E Connecting Peripheral Equipment Connection when the PN-ZB02 optional is attachedConnecting Peripheral Equipment 13 EMultiple monitor connection Connection with video cableConnect the monitors in order Connection with the control kit optionalSet the ID No Preparing the Remote Control Unit Connecting the Power CordInstalling the batteries Remote control operation rangeBinding Cables Removing the HandlesAffixing the Protection Covers Be sure the handles are attached securelyTurning Power On/Off Turning on the main powerTurning power on/off Disabling power on/off operationsInput Input mode selection VOL +/- Volume adjustmentBasic Operation MuteBasic Operation 19 EDisplay Basic Operation NSwitching the screen size Wide Zoom NormalDot by Dot Cut offRemote Control Mode 21 EThis Monitor only Specified MonitorMenu Items Displaying the menu screenNExample of operation NMenu screen display23 E Menu item detailsNSCREEN Menu Items NPICTUREMenu Items NSETUPNAUDIO 25 E Menu Items NOPTION NMULTI 27 EMenu Items NPIP/PbyP NEnlarge Menu Items NDual screen displayPIP 29 E NZOOM2 Special SettingNSCHEDULE NAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment 31 E Communication procedure Controlling the Monitor with a PC RS-232CPC connection Communication conditions33 E NCommunication intervalNCommands for ID control Controlling the Monitor with a PC RS-232CNID numbers Advanced operation35 E NRepeater controlVOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←Setting of the Gamma user data NTo transfer the Gamma user dataNSaving the Gamma user data NActivating the Gamma user dataRS-232C command table Power control/Input mode selectionHow to read the command table 37 EControlling the Monitor with a PC RS-232C Screen menu 39 E Controlling the Monitor with a PC RS-232C Picture menuSetup menu Controlling the Monitor with a PC RS-232C Audio menu41 E Controlling the Monitor with a PC RS-232C Option menuControlling the Monitor with a PC RS-232C Multi menu Image Position Epos settingHorizontal orientation Vertical orientation 43 E Initialization/Functional Restriction Setting Function menuControlling the Monitor with a PC RS-232C PIP/PbyP menu Commands for setting of the Gamma user data Controlling the Monitor with a PC RS-232C OthersSettings to connect to a LAN Controlling the Monitor with a PC LAN45 E To set on the monitorDefault Gateway 0.0 Controlling the Monitor with a PC LAN To set from a PCControlling with a PC 47 EControlling the Monitor with a PC LAN Standby mode, Power on is the operation available Information about this monitor appearsUser Name / Password 49 EDNS Server Accept IP AddressInstallation Information NAME/LOCATION AuthenticationAccount Name / Password Monitor Name51 E Recipient E-MAIL AddressesCondition ConfirmationSnmp Setting Trap SettingTrap Setting of Authentication Error VersionTroubleshooting 53 ETroubleshooting Specifications NPN-V602 Product SpecificationsNPN-ZR01 optional Product Specifications 55 ESpecifications NDimensional Drawings NPower managementNPOWER Limited See Set to ensure maximum power consumption. SeeSpecifications NCompatible signal timing PC 57 ESpecifications NCompatible signal timing AV 59 E PN-V602 Mu EN11H1
Related manuals
Manual 28 pages 8.65 Kb Manual 60 pages 10.1 Kb