<MAIN MENU> appears.
<MAIN MENU>
DISPLAY
TIMER PROGRAM RECORDING SET UP REAR TERMINAL MAINTENANCE CLOCK/FIRST TIME SET UP
<REAR TERMINAL>
CALL OUT WRNG•TAPE END
CLOCK OUT REC- 1
MODE OUTREC
REC IN REC-START/STOP

Remote Recording

This function permits you to control the start/end of recording from the remote place. The VCR starts recording while the REC IN terminal is grounded.

1. Display <REAR TERMINAL> menu.

2. Set REC IN to REC-START/STOP.

3.Press MENU button.

The day and present time display appears on screen.

page 27 for remote recording connection.

Note

An index signal will not be recorded during remote recording.

Series or timer recording function cannot be used with remote recording at the same time.

Repeat Recording

With this function, when the tape reaches its end during recording, the VCR rewinds the tape and starts recording again.

1. Press MENU button.

When the tape reaches its end during recording

The following functions are automatically engaged when the tape ends during recording.

TAPE END

When there are alarm

When there is NO alarm

setting

recordings on tape

recording on tape

 

 

 

 

 

The tape is rewound

ALARM•

The tape stops.(*)

automatically to the

PROT

beginning and then

 

 

 

recording is resumed.

 

 

 

STOP

The tape stops.

 

 

 

 

 

The tape is rewound automatically to the

REWIND

beginning (except in timer recording) and

 

then stops.

 

 

 

 

 

The tape is rewound automatically to the

REPEAT

beginning and then recording is resumed

 

(also recording over existing alarms).

 

 

 

*To repeat recording on the same tape again, eject the tape once and reinsert.

One shot/Interval Recording

One shot recording allows you to control the number of fields to be recorded when the REC button is pressed or the REC IN terminal is grounded. Interval recording is made at the selected

2. Turn JOG to select CLOCK/FIRST

TIME SET UP and turn SHUTTLE to

the right.

<FIRST TIME SET UP> menu

appears.

<FIRST TIME SET UP>

 

TIME DATE ADJUST

STOP

TAPE END

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

number of fields and at the selected interval.

1.Press REC/PLAY MODE button on the front panel to set the recording mode to 0H.

3.

Turn JOG to select TAPE END and

 

turn SHUTTLE to the right.

4.

Turn JOG to select REPEAT or

 

ALARM•PROT and turn SHUTTLE to

 

the right.

 

Refer to the table below for

 

REPEAT and ALARM•PROT.

 

Repeat indicator ( ) illuminates

 

on the fluorescent display.

<FIRST TIME SET UP>

 

TIME DATE ADJUST

STOP

TAPE END

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

<FIRST TIME SET UP>

 

TIME DATE ADJUST

REPEAT

TAPE END

QUASI V-SYNC

ON

VIDEO MODE

AUTO

TAPE LENGTH

T-120

BUZZER

WRNG

2.

Press MENU button.

 

<MAIN MENU> appears.

3.

Turn JOG to select RECORDING SET

 

UP and turn SHUTTLE to the right.

 

<RECORDING SET UP> menu

 

appears.

4.

Turn JOG to select ONE

 

SHOT•FIELDand turn SHUTTLE to

 

the right.

<MAIN MENU>

DISPLAY

TIMER PROGRAM RECORDING SET UP REAR TERMINAL MAINTENANCE

<RECORDING SET UP>

6H

ALARM REC MODE

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

1

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

1

ONE SHOT•INTERVAL

10S

5.Press MENU button.

• The day and present time display appears on screen.

5.

Turn JOG to select the number of

 

recording field and turn SHUTTLE to

 

the right.

6.

Turn JOG to select ONE

 

SHOT•INTERVALand turn SHUTTLE

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

10S

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

10S

to the right.

For one shot recording, setup step 7 only:

7.Turn JOG to select SHOT and turn SHUTTLE to the right.

For interval recording, setup step 8 only:

8.Turn JOG to select the recording interval and turn SHUTTLE to the right.

9.Press REC button.

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

SHOT

ALARM REC DURATION

1M

EMERGENCY REC

OFF

SUPER RESOLUTION

ON

ONE SHOT•FIELD

5

ONE SHOT•INTERVAL

30S

The one shot recording will be on standby mode.

The VCR starts the interval recording with the interval time selected in step 6 above.

10.To start one shot recording, press REC button again or switch the REC IN terminal on the rear panel to the ground.

Reference page

Advanced Functions 13

Image 17
Contents Super VHS ET Expansion Technology ADV096HDAvertissement Important Safeguards Information Important SafeguardsIii Introduction Contents FeaturesControls and Functions Controls and Functions ALM Mode OUTRST RECBasic Functions Loading/Unloading a TapeRecording/playback time Manual RecordingAudio recording/playback Recording Check FunctionPlayback 32 for Tape END settingRewinding a tape Fast forwarding a tapeJOG dial Shuttle ring Adjusting the ClockWhen adjusting the clock to the exact second Program to Record menu appears Recording Techniques Advanced Functions Special day of the week Holiday set upAlarm Recording Recording Techniques Display during alarm recordingEmergency Recording Series RecordingRemote Recording When the tape reaches its end during recordingRepeat Recording One shot/Interval RecordingSynchronous Recording Recording time modeVCR Number of camerasMemory backup in case of power failure Additional FeaturesDisplaying/clearing the alarm list After a power failureSpecial Effects Playback Additional FeaturesTracking adjustment Adjustment during PlaybackPicture quality adjustment Vertical adjustment picture vibration at the top and bottomCounter memory stop Searching TechniquesIndex search Skip searchTime Date Search menu appears Time date searchConnecting to a Personal Computer Configuring the time lapse VCRRS-232C setting Command Commands set to the VCR Commands from personal computerStatus Response codes from the VCR Status Response codes from the VCR to outsideCommands and Responses Using with Personal Computer100=MAIN Menu =STOP, 1=REWIND, 2=REPEAT =SERIES, 1=REC-START/STOP =SYNC REC Error codeConnecting with Cctv camera, monitor and sensor InstallationAlarm Recording Connection Connections for Various FunctionsSeries Recording Connection Connection for External Time Clock AdjustmentRemote Recording Connection Synchronous Recording ConnectionExternal time clock adjustment Setting the ClockSetting the current time to exact second Set the menus by the following steps Press Menu button Setting the MenusMenu Chart Setting the Menus Power Power Loss ListShotfield ShotintervalRS-232C Others Before Calling for ServiceSymptomRemedy Playback Monitor Cause Remedy To turn off the indicator Self-diagnostic functionWhen the tape ends Lack of video signal inputCLK OUT signal Control Input/Output Signals and CircuitALM/RST/REC in terminals screw ALM/MODE/CALL OUT terminals screwGeneral SpecificationsPage Page 872C276B9 8200-0206-02