American Dynamics ADV096HD operation manual RS-232C

Page 36
: The buzzer sounds when there is any malfunction in the VCR.
: The VCR automatically switches the circuits according to type of the input/playback video signal, color or black & white.
: Select for recording or playback in black & white.

Setting the Menus (Cont.)

FIRST TIME SET UP

Setting the present time, date and

<FIRST TIME SET UP>

 

Daylight Saving Time settings (TIME

TIME DATE ADJUST

STOP

DATE ADJUST)

TAPE END

QUASI V-SYNC

ON

page 28

VIDEO MODE

AUTO

TAPE LENGTH

T-120

 

BUZZER

WRNG

 

RS-232C

 

Setting operation of VCR when the tape reaches its end during recording or playback (TAPE END)

The VCR’s function when the tape reaches its end during recording is as follows.

STOP : The tape stops, the indication “End” appears on the fluorescent display and “TAPE END” on screen. When CALL OUT is set to WRNG•TAPE END, a call signal is output from

WRNG•REMAIN : The buzzer sounds when there is any malfunction in the VCR or the tape has approximately 9 minutes (at 6H mode) left.

OFF

: The buzzer does not sound.

Note

To stop the buzzer:

Press MENU button once. If <MAIN MENU> appears, press MENU button again to exit the menu. When the VCR is locked, press LOCK button to unlock the VCR, then the buzzer stops.

Setting the RS-232C parameters

See the next section.

RS-232C

the CALL OUT terminal.

REWIND : Rewinds the tape to the beginning and stops (except during timer recording). When CALL OUT is set to WRNG•TAPE END and a tape reaches its end, a call signal is output for 2 seconds from the CALL OUT terminal.

REPEAT : Rewinds the tape to the beginning and resumes the recording. When CALL OUT is set to

Setting the transmission rate

(TRANSMISSION RATE)

When JOG is turned, the display will be switched in the order of 1200 (bps) 2400 4800 9600 1200

...

Setting the data bit length (DATA

<RS-232C>

1200

TRANSMISSION RATE

DATA BIT LENGTH

8BIT

STOP BIT LENGTH

1BIT

PARITY BIT

NONE

DELIMITER<SEND>

CR•LF

DELIMITER<RECEIVE>

CR

VCR ADDRESS

NONE

WRNG•TAPE END and a tape reaches its end, a call signal is output for 2 seconds from the CALL OUT terminal.

ALARM•PROT (alarm protection) :

If any alarm recordings are present on the tape and the tape stops, the indication “End” appears on the fluorescent display and “TAPE END” on screen. When CALL OUT is set to WRNG•TAPE END, a call signal is output from the CALL OUT terminal. If there is no alarm recording, the VCR rewinds the tape to the beginning and resumes the recording.

Go to page 8 for the VCR’s function when the tape reaches its end during playback.

Setting Quasi-V-sync on or off (QUASI V-SYNC)

ON : Quasi-V-sync. signal is inserted to the video output

signal in the special effects playback ( page 16) or normal playback in L18H-128H or 0H mode.

OFF : Quasi-V-sync. signal is not inserted.

Note

Some multiplexers may require QUASI V-SYNC to be OFF in order to work properly.

Setting the playback/recording color mode (VIDEO MODE)

AUTO

B/W

Setting the tape length (TAPE LENGTH)

T-120 : Select when using a T-120 tape.

T-160 : Select when using a T-160 tape.

Setting to sound buzzer during warning (BUZZER)

WRNG

WRNG•TAPE END : The buzzer sounds when there is any malfunction in the VCR or the tape reaches its end.

BIT LENGTH)

When JOG is turned, the display will be switched in the order of

8BIT 7BIT 8BIT ...

Setting the stop bit length (STOP BIT LENGTH)

When JOG is turned, the display will be switched in the order of

1BIT 2BIT 1BIT ...

Setting the parity bit (PARITY BIT)

When JOG is turned, the display will be switched in the order of

NONE ODD EVEN NONE ...

Setting a character marking the end of a status or error code (DELIMITER<SEND>)

When JOG is turned, the display will be switched in the order of

CR•LF CR CR•LF ...

Setting a character marking the end of a command (DELIMITER<RECEIVE>)

When JOG is turned, the display will be switched in the order of

CR•LF CR CR•LF ...

Setting the ID number of the VCR (VCR ADDRESS)

When JOG is turned, the display will be switched in the order of NONE VCR01 VCR02 ..... VCR254 VCR255.

32 Installation

Note A point to notice

Info. Supplementary information

Image 36
Contents ADV096HD Super VHS ET Expansion TechnologyAvertissement Important Safeguards Important Safeguards IiiInformation Introduction Features ContentsControls and Functions Controls and Functions Mode OUT ALMRST RECLoading/Unloading a Tape Basic FunctionsManual Recording Recording/playback timeAudio recording/playback Recording Check Function32 for Tape END setting PlaybackRewinding a tape Fast forwarding a tapeAdjusting the Clock When adjusting the clock to the exact secondJOG dial Shuttle ring Recording Techniques Advanced FunctionsProgram to Record menu appears Holiday set up Alarm RecordingSpecial day of the week Display during alarm recording Recording TechniquesEmergency Recording Series RecordingWhen the tape reaches its end during recording Remote RecordingRepeat Recording One shot/Interval RecordingRecording time mode Synchronous RecordingVCR Number of camerasAdditional Features Memory backup in case of power failureDisplaying/clearing the alarm list After a power failureAdditional Features Special Effects PlaybackAdjustment during Playback Tracking adjustmentPicture quality adjustment Vertical adjustment picture vibration at the top and bottomSearching Techniques Counter memory stopIndex search Skip searchTime date search Time Date Search menu appearsConfiguring the time lapse VCR RS-232C settingConnecting to a Personal Computer Commands from personal computer Command Commands set to the VCRStatus Response codes from the VCR Status Response codes from the VCR to outsideUsing with Personal Computer Commands and Responses100=MAIN Menu =STOP, 1=REWIND, 2=REPEAT Error code =SERIES, 1=REC-START/STOP =SYNC RECInstallation Connecting with Cctv camera, monitor and sensorAlarm Recording Connection Connections for Various FunctionsConnection for External Time Clock Adjustment Series Recording ConnectionRemote Recording Connection Synchronous Recording ConnectionSetting the Clock Setting the current time to exact secondExternal time clock adjustment Setting the Menus Menu ChartSet the menus by the following steps Press Menu button Setting the Menus Power Loss List PowerShotfield ShotintervalRS-232C Before Calling for Service SymptomRemedyOthers Playback Self-diagnostic function Monitor Cause Remedy To turn off the indicatorWhen the tape ends Lack of video signal inputControl Input/Output Signals and Circuit CLK OUT signalALM/RST/REC in terminals screw ALM/MODE/CALL OUT terminals screwSpecifications GeneralPage Page 872C276B9 8200-0206-02