Peerless Industries PT632, PT630 manual Installation to Solid Concrete or Cinder Block

Page 5

Installation to Solid Concrete or Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

1

Make sure that wall plate (A) is level, use it as a

template to mark two mounting holes. Drill two 5/16"

(8 mm) dia. holes to a minimum depth of 2.5"

(64 mm). Insert anchors (E) in holes flush with wall as shown. Place wall plate over anchors and secure with two #14 x 2.5" screws (D). Level, then tighten all

fasteners.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to load-bearing concrete.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws.

If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

1

concrete

surface

E

Drill holes and insert anchors (E).

2

A

 

 

D

E

Place plate (A) over anchors (D) and secure with screws (E).

3

Tighten all fasteners.

solid concrete

cinder block

CUTAWAY VIEW

 

INCORRECT

 

CORRECT

 

wall

concrete

wall

 

concrete

 

 

plate

 

 

 

plate

 

 

 

E

 

 

 

 

 

 

 

 

A

 

plaster/

 

plaster/

 

 

drywall

 

drywall

D

 

 

 

 

 

 

5 of 34

ISSUED: 11-19-07 SHEET #: 202-9245-2 07-28-09

Image 5
Contents Model # PT630 PT632 FeaturesTable of Contents Tools Needed for AssemblyParts List Installation to Wood Stud Wall Installation to Solid Concrete or Cinder Block For Vesa 75 Mounting Pattern Ing plate B to back of screen using four M4 x 10 mmChoose hole pattern as shown below. Attach mount For Vesa 100 Mounting PatternFor Vesa 200 x 200 Mounting Pattern 1FOR Vesa 200 x 100 Mounting PatternTOP View Installing and Removing Flat Panel ScreenL US PT630 PT632 CaracterísticasHerramientas necesarias para el ensamblaje AdvertenciaContenido Construcción DE LA Pared Accesorios Necesarios11 de Lista de piezas12 de Instalación en una pared con montante de madera único13 de EN EL Caso DE LA Configuración DE Montaje Vesa EN EL Caso DE LA Configuración DEMontaje Vesa Escoja un patrón de agujeros, como se muestra abajoEN EL Caso DE LA Configuración DE Montaje Vesa 200 x EN EL Caso DE LA Configuración DE MontajeVesa 200 x 15 de16 de PrecauciónInstalación y desinstalación de la pantalla plana PT630 PT632 Caractéristiques Outils nécessaires au montage AvertissementTabla de contenido Type DE MUR Pièces DE Fixation Requises19 sur PT630 PT632 DescriptionPièce no o 20 sur Installation sur un mur à montant en bois simple21 sur Choisissez la configuration de trous illustrée ci Pour LA Configuration DE MontagePour LA Configuration DE Montage Vesa Vesa23 sur 1POUR LA Configuration DE Montage Vesa 200 xPour LA Configuration DE Montage Vesa 200 x 24 sur Mise EN GardeMontage et démontage d’un écran plat PT630 PT632 Merkmale Inhaltsverzeichnis Für den Zusammenbau erforderliche WerkzeugeDeutsch Wandkonstruktion Erforderliche BefestigungsteileTeileliste Installation zu Holzständerreihel 29 von Installation zu massivbeton oder porenbetonsteinBei Montagemuster Vesa AchtungBEI Montagemuster Vesa 200 x 1BEI Montagemuster Vesa 200 xAnbringung und Abnahme des Flachbildschirms VorsichtLimited FIVE-YEAR Warranty Garantie DE Cinq ANS