Maintenance Indicators
■The warning lights (power indicator, lamp indicator and temperature warning indicator) on the projector indicate problems inside the projector.
■If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the projector will enter standby mode. After the projector has entered standby mode, follow the procedures given below.
Top View
Temperature warning indicator
Lamp indicator
Power indicator
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
“” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-
tor will enter standby mode. After “” appears, be sure to perform the measures described on page 54.
About the lamp indicator
■When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be displayed on the screen. When the percentage becomes 0%, it will change to (red), the lamp will automatically turn off and then the projector will automatically enter standby mode. At this time, the lamp indicator will illuminate in red.
■If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on.
Indicators on the Projector
Power indicator | Green on | Normal (Standby) | |
|
|
| |
| Red on | Normal (Power on) | |
|
|
| |
| Green blinks | Abnormal (See page 54.) | |
|
|
| |
| Red blinks | Normal (Cooling) | |
|
|
| |
Lamp indicator | Green on | Normal | |
|
|
| |
| Green blinks | The lamp is warming up or shutting down. | |
|
|
| |
| Red on | The lamp is shut down abnormally or | |
|
| requires to be changed. (See page 54.) | |
|
|
| |
Temperature warning | Off | Normal | |
indicator |
|
| |
Red on | The internal temperature is abnormally | ||
| |||
|
| high. (See page 54.) | |
|
|
|
53