Basic Configuration | DRS5116 |
|
|
16.4.5. Setting by Channel
Alarm Source (*=All)
-With the “Alarm Source” menu, it is possible to select up to 4 sensor/MD and text input.
-For setting sensor/MD, press the related number button.
-Set text as “On/Off” with the [ARROW] button.
-Set a PTZ preset position according to the alarm input.
Recording Speed/Quality
There are four conditions; Low/Standard/High/Custom.
All conditions except “Custom” synchronize “Speed (fps)” and “Quality” automatically; “Low” setting is 1fps/Q5; “Standard” setting is 5fps/Q5; “High” setting is 15fps/Q5. When using the “Custom” setting, Speed (fps) and Quality can be set separately.
Pre Alarm (sec)
Set a value up to 10 seconds to record video
Post Alarm (sec)
Set a value up to 60 seconds to maintain recording conditions
Wren | 2003. 09. 06 (v 1.0) | 90 |