Linear SLR, SLD Loop Layout Illustration, Loop Sealant, USE Relief Cuts AT Corners, Slr Slc Sld 

Page 19

Loop Layout Illustration

 

3/8"

LOOP SEALANT

MULTIPLE TURNS

REFER TO LOOP

INSTALLATION NOTES

FOR DETAILS

 

 

 

 

2"

 

 

 

 

 

 

2" MAX.

TWIST WIRE FROM END OF LOOPS BACK TO OPERATOR AT LEAST SIX TIMES PER FOOT

 

 

 

 

USE RELIEF CUTS AT CORNERS

 

 

 

 

 

 

 

SEPARATE PEDESTRIAN

GATE REQUIRED 7 FEET

MINIMUM DISTANCE FROM GATE

SLR SLC SLD 

Slide Gate Operator Installation Guide

 

- 17 -

227968 Revision X13 2-3-09

Image 19
Contents SLR SLC SLD Table of Contents Gate Operator Classifications Before You BeginAlways Check the Gate’s Action Regulatory WarningsAC Power Wiring Wiring SpecificationsDC Control and Accessory Wiring Gate Post Mounting Pad InstallationMounting Pad Specifications Gate PreparationEND of Gate Pipe Shown Reference only Gate Bracket and Chain AssemblyOperator Preparation Operator SetupLimit Nuts Fine Adjustment Limit Nuts Rough AdjustmentRIGHT-HAND Installation Connectors Controller FeaturesBlinks if Connection has Failed Maint Alert SET Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Open Direction Current Setting Run Alarm and Pre-start AlarmMaximum Close Direction Current Setting Maximum Run Time Entering Advanced Programming ModeSingle Button Input Setup Advanced Controller ProgrammingPower Failure Mode Auxiliary Relay ModeReverse Delay Time Low Power ModeMid-travel Stop Position Reset Cycle CountMaintenance Alert Trigger Soft Start/Stop DurationRadio Transmitter Learn Radio EnableAntenna Installation Reset Controller to Factory DefaultsSLR SLC SLD  Loop Layout IllustrationLoop Sealant USE Relief Cuts AT CornersSafety Edge Layout Illustration Safety Edge Layout Illustration #2 Photoeye Installation Illustration Entrapment Zone #3 Pickets Space Smaller than 2 1/4Entrapment Zone #1 Gate Bracket Bolted to Channel Track Gate InstallationShield Dual Gate InstallationsOpen and Close Limit settings Operator #1Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting Optional Parts Model SLR Exploded ViewOptional Torque Limiter Model SLC Exploded ViewCapacitors For drives 34 to 47 feet wideLimiter Model SLD Exploded ViewModel SLD Mechanical Parts List When NEW Model SLD MaintenanceBattery Maintenance DC Motor Brush ReplacementGeneral Preventative MaintenanceMonth Preventative Maintenance FCC NoticeInstaller Customer Gate Operator Installation Checklist