Linear SLC, SLD, SLR manual Pickets Space Smaller than 2 1/4, Entrapment Zone #3, Entrapment Zone #1

Page 23

SLR SLC SLD  Slide Gate Operator

PICKETS SPACE SMALLER THAN 2 1/4"

MESH WITH OPENINGS

SMALLER THAN 2 1/4"

OR

TO A MINIMUM HEIGHT OF 48" ABOVE GROUND OVER ENTIRE GATE LENGTH

Picket Gate Installation

Installation Guide

- 21 -

227968 Revision X13 2-3-09

CARD READER

ON STAND

SEPARATE PEDESTRIAN GATE REQUIRED

7 FT. MINIMUM DISTANCE AWAY FROM GATE

ENTRAPMENT ZONE

#2 (BOTH SIDES OF GATE)

ENTRAPMENT ZONE #3

(BEHIND GATE)

PHOTOEYE BEHIND

GATE

EDGES SHOWN ON LEADING AND

TRAILING EDGES OF GATE, AND

ON POSTS

REVERSING PHOTOEYE

ACROSS DRIVE

ENTRAPMENT ZONE #1

POSSIBLE LOCATIONS FOR CONTACT AND NON-CONTACT DEVICES SHOWN ABOVE. OTHER AREAS OF ENTRAPMENT MAY EXIST DEPENDING ON EACH SPECIFIC INSTALLATION.

REFER TO INSTALLATION MANUAL FOR ADDITIONAL DETAILS

FOR THE INSTALLATION AND WIRING OF LOOPS, EDGES, AND

PHOTOEYES.

Image 23
Contents SLR SLC SLD Table of Contents Gate Operator Classifications Before You BeginAlways Check the Gate’s Action Regulatory WarningsDC Control and Accessory Wiring Wiring SpecificationsAC Power Wiring Gate Post Mounting Pad InstallationMounting Pad Specifications Gate PreparationEND of Gate Pipe Shown Reference only Gate Bracket and Chain AssemblyOperator Preparation Operator SetupRIGHT-HAND Installation Limit Nuts Rough AdjustmentLimit Nuts Fine Adjustment Connectors Controller FeaturesBlinks if Connection has Failed Maint Alert SET Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Close Direction Current Setting Run Alarm and Pre-start AlarmMaximum Open Direction Current Setting Maximum Run Time Entering Advanced Programming ModeSingle Button Input Setup Advanced Controller ProgrammingPower Failure Mode Auxiliary Relay ModeReverse Delay Time Low Power ModeMid-travel Stop Position Reset Cycle CountMaintenance Alert Trigger Soft Start/Stop DurationRadio Transmitter Learn Radio EnableAntenna Installation Reset Controller to Factory DefaultsSLR SLC SLD  Loop Layout IllustrationLoop Sealant USE Relief Cuts AT CornersSafety Edge Layout Illustration Safety Edge Layout Illustration #2 Photoeye Installation Illustration Entrapment Zone #1 Pickets Space Smaller than 2 1/4Entrapment Zone #3 Gate Bracket Bolted to Channel Track Gate InstallationShield Dual Gate InstallationsOpen and Close Limit settings Operator #1Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting Optional Parts Model SLR Exploded ViewOptional Torque Limiter Model SLC Exploded ViewCapacitors For drives 34 to 47 feet wideLimiter Model SLD Exploded ViewModel SLD Mechanical Parts List When NEW Model SLD MaintenanceBattery Maintenance DC Motor Brush ReplacementGeneral Preventative MaintenanceMonth Preventative Maintenance FCC NoticeInstaller Customer Gate Operator Installation Checklist