Linear SLR, SLD, SLC manual Indicator Descriptions, Blinks if Connection has Failed Maint Alert SET

Page 10

Indicator Descriptions

INDICATOR DEFINITION

OPERATION

PROGRAMMING

INDICATION WHEN LIT

DURING NORMAL OPERATION

INDICATION WHEN LIT

DURING PROGRAMMING

24 VOLT INPUT

 

LOW VOLTAGE AC POWER IS PRESENT

 

POWER

 

 

 

 

 

 

 

 

 

24 VOLT DC

 

LOW VOLTAGE DC POWER IS PRESENT

 

ACCY POWER

 

 

 

 

 

 

 

 

 

 

 

OPEN SIGNAL PRESENT FROM THE INTERNAL

 

OPEN

 

RECEIVER OR AN EXTERNAL DEVICE

 

 

 

CONNECTED TO THE OPEN INPUT TERMINAL

 

 

 

 

 

CLOSE

 

CLOSE SIGNAL IS PRESENT FROM A DEVICE

 

 

CONNECTED TO THE CLOSE INPUT TERMINAL

 

 

 

 

 

 

 

 

STOP

 

STOP INPUT TERMINAL IS OPEN AND

 

 

NOT CONNECTED TO COMMON

 

 

 

 

 

 

 

 

PROGRAM

 

 

CONTROLLER IS IN PROGRAMMING MODE

 

 

 

 

REVERSE

DELAY SET

SIGNAL FROM REVERSING DEVICE IS PRESENT

SET REVERSE DELAY TIME

 

 

 

 

LOCKOUT

ALARM SET

CONTROLS AND OPERATOR ARE LOCKED OUT

SET RUN ALARM AND PRE-START ALARM

BECAUSE OF EXISTING TROUBLE CONDITION

 

 

 

 

 

 

 

RADIO

LEARN

BUILT-IN RECEIVER IS DETECTING A RADIO

TRANSMITTERS CAN BE ENTERED INTO

SIGNAL FROM A REMOTE CONTROL

MEMORY (UP TO 40 TRANSMITTERS)

 

 

 

 

 

 

OPEN CURRENT

SET

MOTOR CURRENT HAS EXCEEDED THE

SET MAXIMUM OPEN CURRENT

OPEN CURRENT SETTING WHILE OPENING

 

 

 

 

 

 

 

 

 

OPEN OBSTRUCTION TERMINAL CONNECTED

 

OPEN OBSTR

MGT 2 SET

TO COMMON BY BEAM OR SAFETY EDGE, OR

SET MGT #2 FUNCTION

 

 

SIGNAL FROM MGT OBSTACLE TRANSMITTER

 

 

 

 

 

OPEN RELAY

LH/RH SET

OPEN RELAY IS ACTIVATED

SET LEFT-HAND RIGHT-HAND OPERATION

 

 

 

 

OPEN LIMIT

BRAKE DELAY

OPEN LIMIT SWITCH IS ACTIVATED

 

 

 

 

 

CLOSE CURRENT

SET

MOTOR CURRENT HAS EXCEEDED THE

SET MAXIMUM CLOSE CURRENT

CLOSE CURRENT SETTING WHILE CLOSING

 

 

 

 

 

 

 

 

 

CLOSE OBSTRUCTION TERMINAL CONNECTED

 

CLOSE OBSTR

MGT 1 SET

TO COMMON BY BEAM OR SAFETY EDGE, OR

SET MGT #1 FUNCTION

 

 

SIGNAL FROM MGT OBSTACLE TRANSMITTER

 

 

 

 

 

CLOSE RELAY

AUTO CLOSE SET

CLOSE RELAY IS ACTIVATED

SET AUTO-CLOSE TIME

 

 

 

 

CLOSE LIMIT

AC DC SET

CLOSE LIMIT SWITCH IS ACTIVATED

SET MOTOR TYPE

 

 

 

 

SINGLE

SET

SINGLE TERMINAL CONNECTED TO COMMON

SET SINGLE BUTTON INPUT FUNCTION

BY AN EXTERNAL PUSHBUTTON OR RADIO

 

 

 

 

 

 

 

MAX RUN

SET

MAXIMUM RUN TIMER HAS BEEN EXCEEDED

SET MAXIMUM RUN TIME

 

 

 

 

COMM LINK

SET

DUAL OPERATOR CONNECTION DETECTED,

 

BLINKS IF CONNECTION HAS FAILED

 

 

 

 

 

 

 

 

MAINT ALERT

SET

MAINTENANCE IS REQUIRED ON OPERATOR

SET MAINTENANCE ALERT CYCLE COUNT

 

 

 

 

"RL"

LEFT OR RIGHT HAND OPERATION

APEX FUNCTION DISPLAY INDICATIONS

MOTOR TYPE

"MO" SELECTION

"PM"

SINGLE OR DUAL GATE

"RT"

MAXIMUM RUN TIMER

LOW POWER

"LP" MODE

"RA"

RADIO ENABLE

"AC"

"RP"

"OC"

"CC"

"AD"

AUTO CLOSE

TIMER

RUN ALARM PRE-START ALARM

MAXIMUM OPEN CURRENT

MAXIMUM CLOSE CURRENT

ADVANCED PROGRAMMING

"SB"

"SM"

"ST"

"AR"

"RD"

SINGLE BUTTON INPUT SETUP

STAGGER

MODE

STAGGER

TIME

AUXILIARY RELAY MODE

REVERSE

DELAY TIME

"FS"

"SS"

"CT"

"MA"

"MT"

POWER

FAILURE MODE

SOFT START/STOP DURATION

RESET CYCLE

COUNT

MAINTENANCE ALERT TRIGGER

MID-TRAVEL

STOP POSITION

"TL"

"TD"

"ML"

"MD"

"CL"

LEARN TRANSMITTERS

DELETE TRANSMITTERS

LEARN MGT TRANSMITTERS

ERASE MGT TRANSMITTERS

RESET TO FACTORY DEFAULTS

SLR SLC SLD  Slide Gate Operator Installation Guide

- 8 -

227968 Revision X13 2-3-09

Image 10
Contents SLR SLC SLD Table of Contents Regulatory Warnings Before You BeginAlways Check the Gate’s Action Gate Operator ClassificationsAC Power Wiring Wiring SpecificationsDC Control and Accessory Wiring Gate Preparation Mounting Pad InstallationMounting Pad Specifications Gate PostGate Bracket and Chain Assembly END of Gate Pipe Shown Reference onlyOperator Setup Operator PreparationLimit Nuts Fine Adjustment Limit Nuts Rough AdjustmentRIGHT-HAND Installation Controller Features ConnectorsIndicator Descriptions Blinks if Connection has Failed Maint Alert SETTerminal Descriptions Terminal Group FunctionOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Open Direction Current Setting Run Alarm and Pre-start AlarmMaximum Close Direction Current Setting Advanced Controller Programming Entering Advanced Programming ModeSingle Button Input Setup Maximum Run TimeLow Power Mode Auxiliary Relay ModeReverse Delay Time Power Failure ModeSoft Start/Stop Duration Reset Cycle CountMaintenance Alert Trigger Mid-travel Stop PositionReset Controller to Factory Defaults Radio EnableAntenna Installation Radio Transmitter LearnUSE Relief Cuts AT Corners Loop Layout IllustrationLoop Sealant SLR SLC SLD Safety Edge Layout Illustration Safety Edge Layout Illustration #2 Photoeye Installation Illustration Entrapment Zone #3 Pickets Space Smaller than 2 1/4Entrapment Zone #1 Track Gate Installation Gate Bracket Bolted to ChannelOperator #1 Dual Gate InstallationsOpen and Close Limit settings ShieldGate Operation Operation IndicationsComm Link Connection Failure Error IndicationsEntrapment MGT Obstacle Transmitter TroubleTroubleshooting Model SLR Exploded View Optional PartsModel SLC Exploded View Optional Torque LimiterFor drives 34 to 47 feet wide CapacitorsModel SLD Exploded View LimiterModel SLD Mechanical Parts List DC Motor Brush Replacement Model SLD MaintenanceBattery Maintenance When NEWFCC Notice Preventative MaintenanceMonth Preventative Maintenance GeneralGate Operator Installation Checklist Installer Customer