Indications

The easy-to-use 3M Electronic Pipettor - 5mL is pre-programmed to perform the most common dilutions used with 3MPetrifilmPlates and 3MRedigelTests. The self-calibrating, microprocessor-based system reduces the possibility of human error and instrument contamination by controlling pipetting speed, calibration and volume selection. It is a simple yet sophisticated instrument for handling micro- volumes of liquids with high accuracy and precision. Its light-weight and ergonomic controls take the effort out of pipetting to help reduce the risk of repetitive strain injuries that are frequent in manual pipetting.

The 3M Electronic Pipettor 5mL includes:

Pre-programmed diluting, pipetting, and dispensing modes

Self-calibrating, microprocessor-controlled system

Full-grip; low-effort tip ejector

Soft-touch operating button

Open programming mode for user-set pipetting and diluting

Recall button for selecting previous mode

LCD screen for viewing speed, mode and volume

5 speeds for aspiration and dispensing

Cordless operation

Magnetic-mount recharging stand

Replaceable NiMH battery

Weighs less than 6 ounces

Standard Methods for the Examination of Dairy Products (SMEDP) accuracy

Page 2 of 15 - June 2001

Precautions

Always follow Good Laboratory Practices.

Avoid contamination of the tip cone. Do not rest the pipettor on its side. Always place the pipettor in the charging stand when not in use.

Ensure consistent technique to maintain precise results.

Never strike the pipettor tip cone against the tip tray when mounting tips. This can damage internal components.

Avoid excessive shock to pipettor. Do not drop the pipettor, charging stand or AC adapter.

Avoid exposing the unit to extreme temperature changes, humidity and dust.

Avoid rough handling when using the unit. Moderate keystroke pressure is all that is required for all operating buttons.

3

4

Image 2
Contents Description 3M Electronic Pipettor 5mL includes PrecautionsIndications Instructions For Use Connecting the AC AdapterCharging the Pipettor Battery Condition Range or LimitPipettor Programming Power on Display and StartupMode Selection and Mode Recall Program MenuDilution 5mL Total Volume Dilution 1mL Total Volume Repeat Dispensing 1-5 repetitions of 1mL 1mL Pipetting 5mL Pipetting Open Dilution ProgrammingSpeed Selection Bubbles TroubleshootingEr 1 Display Frozen DisplayCleaning the Tip Cone Care and MaintenanceCare and Maintenance Filter ReplacementCalibration Check Chart Battery ReplacementCalibration Check Mode d1, 15, 5mL dilution Accuracy and Precision SpecificationsPipettor Tips TolerancesLimitation of Remedies Limited WarrantyOut of Warranty Service