VIS-CAM System
Figure 29. Connection for LVD to VIS CAM 400.
Table 11 | Wiring for LVD to VIS CAM 400. |
| ||
|
|
|
|
|
| X7 Pin # | Signal | Description | Connection to |
|
|
|
|
|
| 1 | 24V (Fused 0.5A) | Power to laser | Laser power input |
|
|
|
|
|
| 2 | Gnd | Power gnd | Laser ground |
|
|
|
|
|
| 3 | Trigger | Trigger from laser | Trigger out on laser |
|
|
|
|
|
| 4 | RS485- | Transmit to laser | Receive input on laser |
|
|
|
|
|
| 5 | RS485+ | Receive from laser | Transmit output on laser |
|
|
|
|
|
| 6 | Gnd | Communication gnd | Communication gnd on laser |
|
|
|
|
|
| 7 | nc | No connection - | - |
|
|
|
|
|
| 8 | nc | No connection | - |
|
|
|
|
|
The cable must be shielded and the shield connected to the metal at the cable entry in the camera house.
The switch S3 and/or S5 on the
Installing the Vehicle Imaging Subsystem | 31 |