VIS-CAM System
6.2.1Functionality
Power and data connection to the EN camera. The 24V power supply for all camera functions (Camera, I/O Board, light and heaters), Ethernet and RS485 data communication is connected by means of this connector.
6.2.2Connector specification
Connector type: | 16 pole WAGO pluggable terminal block |
Connector on board: | WAGO |
Cable part: | WAGO |
6.2.3Connector signal specifications
6.2.3 (a) Lane Controller interface Description
RS485 two wire
Signal levels:
Standard RS485 communication levels. Electrical interface on the
6.2.3(b) Trigger output Description
The trigger output is balanced and the driver is a RS485 transmitter (LTC1480).
Signal levels
The signal levels are at standard RS485 levels. The specification below is taken from Linear Technologies datasheet for LTC1480:
Table 17 Signal parameters and conditions.
Electrical interface on the J-Panel:
Figure 65. J-Panel electrical interface
|
|
|
66 | Appendix B: |