VIS-CAM System
5.7X15: I/O Board Auxiliary power connector
Figure 62. Auxiliary power connector
5.7.1Functionality
Power outlet for auxiliary equipment.
5.7.2Connector physical Interface
Connector: | 2 pole WAGO pluggable terminal block | ||
PCB part: | WAGO | ||
Cable part: | WAGO | ||
|
|
| |
| Connector pin # | Signal | |
|
|
|
|
| 1 |
| +24V (fused 0.5A) (self resetable) |
|
|
|
|
| 2 |
| Gnd |
|
|
|
|
5.8 Cables
In order to comply with EMC regulations the cable must be shielded and the wires must be twisted pairs. The cable used for the Ethernet signals must be minimum Cat 5e and preferably Cat 6. The wires used for power must be a minimum 0.5 mm2.
5.8.1Cable Specifications
5.8.1 (a) Ethernet:
Category
Characteristic impedance Number of twisted pairs Maximum cable diameter Maximum cable length
Cat 5e or preferably Cat 6
100Ω
15mm
100meters
5.8.1 (b) RS485 and power:
Characteristic impedance | 120 Ω |
Number of twisted pairs | 4 |
Wire dimension | ≥ 0.5mm2 |
Maximum cable diameter | 15 mm |
Maximum cable length | 100 meters |
|
|
|
62 | Appendix A: Camera Functional & Connector Description |