2.3.1. Address Setting

The address code of the EPTZ900/500 should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary coded of the address, and there are 256 addresses can be selected (0 ~ 255, 28 = 256). It also means that there up to 256 dome cameras can cascade on the RS485 bus. The dipswitch setting and the indicated address are represented in the following chart.

Note: The factory default address is 1.

Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing.

CPU

1

ON

ID1

 

2

 

ID2

3

 

ID3

4

 

ID4

5

 

ID5

6

 

ID6

7

 

ID7

8

 

ID8

 

 

 

SW1

SW2

1

 

ON

2

 

 

 

3

 

 

4

 

 

5

 

 

6

 

 

7

 

 

8

 

 

 

 

 

BAUD Protocol

2-14

Image 15
Contents EPTZ900/500 Table of Contents Structure of the Setup Menu Camera Setup Menu EPTZ900/500 Function Setup and OperationIntroduction EPTZ900/500 OverviewPage EPTZ900 EPTZ500 CE FCC EPTZ500 Feature Profile of EPTZ900/500EPTZ900 Baseboard RelayEPTZ500 Baseboard EPTZ900/500 Control Board RelayEPTZ900/500 EPTZ900/500 Quick Operation Guide Work with EKB500 Packing List Cable Needed Power CableVideo Cable ID1 Page Address EVF 1 PELCO-D PELCO-P TYPE-A OFF CAM-0 CAM-1 Rack and Speed Dome Installation Installation Requirements Relay Glove Turn on the power, and start to operate the EPTZ900 Cut the ceiling Page Glove Separately Sold Accessories Pole mount Structure of the Setup Menu EPTZ900/500 Camera Setup MenuCamera Setup Menu Page Page Page Manual Control Mode EPTZ900/500 Function Setup and OperationTour Mode ¾ Delete an alarm link ¾ Set an alarm linkPin # Function EPTZ900 base boardAppendix B Protocol Function CMD2 IDH IDL DATA1 Char Coor=0-19 Char=ASCII code EverFocus Electronics Corp