¾Preset a position: Shift the Joystick to the position you would like to preset, and then press Shift + Position. The system will ask you to enter the preset position number (1~239), and then press Enter to save the position. There are up to 192 positions can be preset.

¾Set the parameter of a preset position: Press Set + Position to set the parameter of a preset position. You can set the going-to speed (1~239), dwell time (1~239 seconds), and the title of the position. Shift the joystick Right/Left to change bits, and shift the Joystick Up/Down to change the alphanumeric characteristic. The available alphanumeric characteristics are 0~9, A~Z, &, ?, !, :, ‘, ., ,, /, -, and a space.

¾Delete a preset position: Press Clr + Position to delete a preset position. The system will ask you to enter the position number that you would like to delete, and then press Enter.

4.4.Tour Mode

In the tour mode, you can set a tour for viewing. There are 16 tours can be set, and 16 preset positions in a tour.

¾One-way tour Mode: Press Tour to enter the tour mode. The system will ask you to enter the tour number you would like to run, and starts the tour after pressing Enter. To preset a tour before running it is necessary.

Preset a one-way tour: Press Set + Tour to preset a one-way tour. The system will ask you to enter preset position numbers (The positions need to be preset). After finish entering all positions, press Stop to quit, and then press Enter to save the tour.

¾To-and-fro tour mode: Press Shift + Tour to run a to-and-fro tour. The system will

4-34

Image 35
Contents EPTZ900/500 Table of Contents Structure of the Setup Menu Camera Setup Menu EPTZ900/500 Function Setup and OperationIntroduction EPTZ900/500 OverviewPage EPTZ900 EPTZ500 CE FCC EPTZ500 Feature Profile of EPTZ900/500EPTZ900 Baseboard RelayEPTZ500 Baseboard EPTZ900/500 Control Board RelayEPTZ900/500 EPTZ900/500 Quick Operation Guide Work with EKB500 Packing List Cable Needed Power CableVideo Cable ID1 Page Address EVF 1 PELCO-D PELCO-P TYPE-A OFF CAM-0 CAM-1 Rack and Speed Dome Installation Installation Requirements Relay Glove Turn on the power, and start to operate the EPTZ900 Cut the ceiling Page Glove Separately Sold Accessories Pole mount Structure of the Setup Menu EPTZ900/500 Camera Setup MenuCamera Setup Menu Page Page Page Manual Control Mode EPTZ900/500 Function Setup and OperationTour Mode ¾ Delete an alarm link ¾ Set an alarm linkPin # Function EPTZ900 base boardAppendix B Protocol Function CMD2 IDH IDL DATA1 Char Coor=0-19 Char=ASCII code EverFocus Electronics Corp