EverFocus EPTZ900 user manual CMD2 IDH IDL DATA1

Page 40

------------------------------

+ -----

------

-----

-----

-------

-----

-----

+

---------------------------------

Set Single Point Alarm Linkage FA

7A-7D

.

.

pp

.

cs

pp=1-192 (position)

Clr Single Point Alarm Linkage FA

7E-81

.

.

AA

.

cs

 

 

Cruise Alarm Linkage Set

FA

82-85

.

.

group

.

cs

group=1-16

 

Cruise Alarm Linkage Cancel

FA

86-89

.

.

AA

.

cs

 

 

------------------------------

+ -----

------

-----

-----

-------

-----

-----

+

---------------------------------

set preset position parameter FA

A0

.

.

pp

.

cs

pp=1-192 (position)

speed to preset position

FA

A1

.

.

speed

.

cs

speed=1-EFh

 

Dwell time at preset position FA

A2

.

.

dwell

.

cs

dwell=1-EFh (seconds)

Set PresetPosition Param Close FA

A3

.

.

AA

.

cs

 

 

------------------------------

+ -----

------

-----

-----

-------

-----

-----

+

---------------------------------

Home Position Set

FA

A4

.

.

AA

.

cs

 

 

Wait time at Home Position

FA

A5

.

.

WaitT

.

cs

WaitT=0-EFh (minutes)

Enable Home position On/Close FA

A6

.

.

on-off

.

cs

on-off=0/1

(0=off, 1=on)

------------------------------

+ -----

------

-----

-----

-------

-----

-----

+

---------------------------------

Clear Preset Position

FA

A7

.

.

pp

.

cs

pp=1-192 (position)

==============================+====== ====== ===== =====

======= ===== =====+=================================

Speed Dome Setup Menu

FA

90

.

.

operate

.

cs

operate=01

Enter menu mode

 

 

 

 

 

 

 

=02

Exit menu mode

 

 

 

 

 

 

 

=03

menu cursor up

 

 

 

 

 

 

 

=04

menu cursor down

 

 

 

 

 

 

 

=05

menu cursor left

 

 

 

 

 

 

 

=06

menu cursor right

 

 

 

 

 

 

 

=07

select option

 

 

 

 

 

 

 

=08

confirm

==============================================================================================================

2-2. Part-II ( Enhance part )

================================================================================================================

 

(B1)

(B2)

(B3)

(B4)

(B5)

(B6)

(B7)

(B8)

 

FUNCTION

CMD1

CMD2

IDH

IDL

DATA1

KB-ID

DATA2

CSUM DESCRIPTION

------------------------------

+

------

-----

----- -----

------ -----

-----

-----+

---------------------------

enhance move

FC

OP

.

.

x-spd

.

y-spd

cs

OP: (0-3)

 

 

 

 

 

 

 

 

 

bit0: (0=right, 1=left)

 

 

 

 

 

 

 

 

 

bit1: (0=up, 1=down)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x-spd=0-EFh

 

 

 

 

 

 

 

 

 

y-spd=0-EFh

4-39

Image 40
Contents EPTZ900/500 Table of Contents EPTZ900/500 Function Setup and Operation Structure of the Setup Menu Camera Setup MenuEPTZ900/500 Overview IntroductionPage EPTZ900 EPTZ500 CE FCC Feature Profile of EPTZ900/500 EPTZ500Relay EPTZ900 BaseboardRelay EPTZ500 Baseboard EPTZ900/500 Control BoardEPTZ900/500 EPTZ900/500 Quick Operation Guide Work with EKB500 Cable Needed Power Cable Packing ListVideo Cable ID1 Page Address EVF 1 PELCO-D PELCO-P TYPE-A OFF CAM-0 CAM-1 Rack and Speed Dome Installation Installation Requirements Relay Glove Turn on the power, and start to operate the EPTZ900 Cut the ceiling Page Glove Separately Sold Accessories Pole mount EPTZ900/500 Camera Setup Menu Structure of the Setup MenuCamera Setup Menu Page Page Page EPTZ900/500 Function Setup and Operation Manual Control ModeTour Mode ¾ Set an alarm link ¾ Delete an alarm linkEPTZ900 base board Pin # FunctionAppendix B Protocol Function CMD2 IDH IDL DATA1 Char Coor=0-19 Char=ASCII code EverFocus Electronics Corp