EverFocus EPTZ900 user manual EVF 1 PELCO-D PELCO-P TYPE-A

Page 18

2.3.2. Communication Protocol Setting

The 1st, 2nd and 3rd bits of the SW2 are used to set communication protocol. The factory default protocol is EVF.

SW2

EVF - 1 PELCO-D PELCO-P TYPE-A

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing.

Set all of protocol switches to ON; the EPTZ900/500 will enter a self-test mode.

2.3.3. Transmission Speed Setting (Baud Rate Setting)

The 4th and 5th bits of the SW2 on the PCB board are used to set the Baud Rate. The default baud rate setting is 9600.

SW2

9600 BPS 4800 BPS 2400 BPS 1200 BPS

Protocol

Baud Rate

PAL / NTSC

Maching Resistance

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

8

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

8

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

8

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

8

 

 

 

 

 

 

 

1

 

ON

 

2

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

5

 

 

 

 

6

 

 

 

 

7

 

 

 

 

 

 

8

 

 

 

 

 

 

 

Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing.

2-17

Image 18
Contents EPTZ900/500 Table of Contents EPTZ900/500 Function Setup and Operation Structure of the Setup Menu Camera Setup MenuEPTZ900/500 Overview IntroductionPage EPTZ900 EPTZ500 CE FCC Feature Profile of EPTZ900/500 EPTZ500Relay EPTZ900 BaseboardRelay EPTZ500 Baseboard EPTZ900/500 Control BoardEPTZ900/500 EPTZ900/500 Quick Operation Guide Work with EKB500 Cable Needed Power Cable Packing ListVideo Cable ID1 Page Address EVF 1 PELCO-D PELCO-P TYPE-A OFF CAM-0 CAM-1 Rack and Speed Dome Installation Installation Requirements Relay Glove Turn on the power, and start to operate the EPTZ900 Cut the ceiling Page Glove Separately Sold Accessories Pole mount EPTZ900/500 Camera Setup Menu Structure of the Setup MenuCamera Setup Menu Page Page Page EPTZ900/500 Function Setup and Operation Manual Control ModeTour Mode ¾ Set an alarm link ¾ Delete an alarm linkEPTZ900 base board Pin # FunctionAppendix B Protocol Function CMD2 IDH IDL DATA1 Char Coor=0-19 Char=ASCII code EverFocus Electronics Corp