Philips Video Camera manual Line Lock Control, Mode, Local Control, Exit ESC to Exit

Page 25

EDC-142E1

 

AE SETUP

EDC-142E2

 

 

MODE

: FULL AUTO

 

SLOW SHUTTER

: AUTO

 

IRIS

: F1.6

 

GAIN

: 2DB

 

BRIGHT

: 30

 

SHUTTER

: AUTO

 

WDR MODE

: ON

 

EXIT (ESC TO EXIT)

 

MODE :

FULL AUTO / SHUTTER PRIO / IRIS PRIO / AGC / MANUAL

SLOW SHUTTER :

AUTO / OFF, ON (MANUAL, SHUTTER PRIO Mode)

IRIS :

CLOSE / F1,6 / F2,0 / F2,8 / F4,0 / F5,6 / F8,0 / F11 / F16 / F22 / F32

GAIN :

OFF, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20dB

 

BRIGHT :

User can adjust brightness level (0 – +90). Level 30 is default.

SHUTTER :

1/1, 1/2, 1/3, 1/6, 1/10, 1/30, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1.000, 1/2.000, 1/5.000, 1/10.000

 

(1/1, 1/2, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/120, 1/250, 1/500, 1/1.000, 1/2.000, 1/4.000, 1/10.000)

WDR MODE :

Wide Dynamic Range Technology uses two shutter speeds in alternative video fields - high and normal - every 60th (or 50th) of

 

a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one

 

portion of an image is brillantly bright while other portions are dark.

EXIT (ESC TO EXIT)

NOTE: Values in ( ) are for PAL Camera. The value is different according to the model.

• LINE LOCK CONTROL

LINE LOCK SETUP

MODE : INTERNAL

PHASE : 125

EXIT (ESC TO EXIT)

MODE :

INTERNAL / EXTERNAL. Adjusts phase of picture with other cameras in EXTERNAL mode.

PHASE :

0~255

EXIT (ESC TO EXIT)

 

• NIGHT SHOT MENU (not at EDC-142E1 and EDC-142E)

The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera sensitive to near infrared. This will set the BLACK & WHITE option to ON automatically.

 

NIGHT SHOT SETUP

 

MODE

: MANUAL

 

LOCAL CONTROL

: OFF

 

EXIT (ESC TO EXIT)

 

MODE:

MANUAL / AUTO / GLOBAL

 

AUTO:

Camera goes in to B&W mode at low light.

 

GLOBAL:

Controlled by the keyboard

 

 

The operator can enable NIGHT SHOT for all dome cameras at the same time. If the NIGHT SHOT mode is set to GLOBAL,

 

9 9 9„ + Enter/Glbl will turn Off the NIGHT SHOT mode „8 8 8” + Enter/Glbl will turn On the NIGHT SHOT mode.

MANUAL:

Controlled by the local setting value

 

LOCAL CONTROL:

ON/OFF will enable and disable Night Shot mode of an individual camera.

EXIT (ESC TO EXIT)

 

 

25

Image 25
Contents Installation and Operating Manual Contents Introduction 1.1 Features Safety InstructionsAssemble bubble ring ass’y Push Bubble ring ass’y Screw Remove windowDifferent version will not support alarm input and output Installation and Configuration 2.1 Package ContentsSTP AWG #24 Basic Configuration of Fastrax II Dome Camera SystemBNC 24VAC Single MultiplexerBNC BNC 1st Main Monitor Spot Monitor Single User with Two Multiplexer1st Multiplexer Pin NoTwo Multiplexer with Slave Keyboard Controller Two Multiplexer with Slave Keyboard Controller method Two Multiplexer with Slave Keyboard Controller methodSW1 Setting Unit for TerminationBeyond ID 999, contact your service provider Setting Address ID of Dome CameraDome ID Off Function Setting Protocol of Dome CameraProtocol CameraConnection Alarm Display RAM Test Check NO. OK Check Aaaa OKGetting Started TitleHow to control On-Screen Menu Utility Accessing On-Screen Menu UtilityMenu ESCScan AUTOSCAN01 Auto Scan SetupEND Angle Quick moveJOY-LEFT to PREV. Save and Exitesc to Cancel Preset SetupFollow steps below to store the Preset positions AUTO/ ManualGuard Tour Setup Shortcut of Preset ProgramScan Type Normal DwellFollow steps below to program the Pattern Pattern Setup TitlePRS Area Title SetupTitle Start END ACB ==== Back Light SharpnessDigital Zoom Not at EDC-142E1EDC-143E WB white balance ControlAE Control Mode Line Lock ControlLocal Control Exit ESC to ExitHome Function Setup Language SetupFollow these steps to program the Home position OSD Display View Angle SetupView Direction Dome OSD DisplayFlip Panning RangeTilt Over Angle Initialize DataDome Reset TroubleshootingProblem Possible Solution System InformationWDR GlossaryShort Cut Key EDP SpecificationsAlarm inputs Alarm processingRemote control BackupDimensional Drawings