Philips Video Camera manual Shutter modes, Synchronization, Video output, Zoom range, Iris control

Page 33

Model

EDC-142E

EDC-141E

 

EDC-143E

EDC-142E1

 

EDC-144E

 

EDC-142E2

EDP

74081

74086

 

74091

74093

 

74100

 

74117

Shutter modes

High and Low Speed shutter

 

High and Low

 

 

 

 

 

 

 

 

Speed shutter

 

 

Synchronization

 

Internal/AC line lock, phase adjustment via remote control

 

White balance

 

Modes: Manual, Automatic, Indoor, Outdoor, ATW

 

Video output

 

 

 

1Vp-p, CVBS, 75ohms, BNC

 

 

 

Zoom range

F1.4-3.0/4.1-73.8mm (18x optical,

 

F1.6/

F1.4/3.8-

 

F1.6~F80/3.5

 

F1.4/3.8-

 

12x digital zoom)

 

3.6~82.8mm

83.6mm (22x

 

~ 91mm (26x

 

83.6mm (22x

 

 

 

 

(23 optical, 10x

optical, 12x

 

optical, 12x

 

optical, 12x

 

 

 

 

digital zoom)

digital zoom)

 

digital zoom)

 

digital zoom)

Horizontal angle of view

48° (Wide); 2.7° (Tele end)

 

54° (Wide); 2.5°

52° (Wide); 2.4°

 

54.2° (Wide);

 

52° (Wide); 2.4°

 

 

 

 

(Tele end)

(Tele end)

 

2.2° (Tele end)

 

(Tele end)

Iris control

 

 

 

Automatic (with manual override)

 

 

 

Focus control

 

 

 

Automatic with manual override

 

 

 

Minimum object distance (MOD)

 

 

 

0.3m

 

 

 

Menu driven set-up

 

 

 

ON/OFF switchable

 

 

 

Text display

 

 

 

16-character labels

 

 

 

Menu languages

English

 

English, German, French, Spanish, Portuguese, Italian, Polish

 

Alarm processing

 

 

Programmable alarm action with selectable priority levels

 

Alarm inputs

 

 

8, selectable between NO and NC

 

Bubble

 

 

 

4.9” (125mm), clear acrylic plastic

 

 

 

Control interfaces

RS-422/RS-485,

RS-422/RS-485, 9600Baud, 999 camera ID adresses selectable. Besides the keyboard control

 

9600Baud, 999

via the eneo EDC-KBD(M) series, the control via matrix switchers and keyboards from Pelco

 

camera ID adres-

(D+P protocol), Ernitec, Philips G3, Sensormatic RS-422, (back channel via RS-422 is not

 

ses selectable.

 

 

activated), Vicon and Dynacolor is available.

 

 

Besides the key-

 

 

 

 

 

 

 

 

 

board control via

 

 

 

 

 

 

 

 

 

the eneo EDC-

 

 

 

 

 

 

 

 

 

KBD(M) series,

 

 

 

 

 

 

 

 

 

the control via

 

 

 

 

 

 

 

 

 

matrix switchers

 

 

 

 

 

 

 

 

 

and keyboards

 

 

 

 

 

 

 

 

 

from Pelco (D+P

 

 

 

 

 

 

 

 

 

protocol), Ernitec,

 

 

 

 

 

 

 

 

 

etc. is available.

 

 

 

 

 

 

 

 

Keyboard control

Direct mode control with Eneo EDC-KBD(M) keyboard series, or in conjunction with the eneo Triplex Multiplexer

 

 

series VBMT/VCMT-8000 and DVR series DLR(2) and DXR

 

Auxiliary outputs

 

 

4 relays with NO/NC contact, 24VDC/1A resistive

 

Remote control

 

 

 

Camera remote settings via keyboard

 

 

 

Operation protection

 

 

 

Available

 

 

 

Backup

Non-volatile back box memory stores all camera and site-specific dome settings

Supply voltage

 

 

18 to 30VAC (24VAC nominal), 50/60Hz

 

 

 

Power consumption

 

 

 

Approx. 20watts

 

 

 

Temperature range

 

 

 

0°C to +50°C

 

 

 

Protection rating

 

 

 

IP40

 

 

 

Housing

 

Black plastic for indoor drop-ceiling mount

 

 

 

Dimensions

 

 

 

See drawing

 

 

 

Weight

1.3kg

 

 

 

1.5kg

 

 

 

33

Image 33
Contents Installation and Operating Manual Contents Introduction 1.1 Features Safety InstructionsAssemble bubble ring ass’y Push Bubble ring ass’y Screw Remove windowDifferent version will not support alarm input and output Installation and Configuration 2.1 Package ContentsBasic Configuration of Fastrax II Dome Camera System STP AWG #24BNC Single Multiplexer 24VACBNC BNC 1st Main Monitor Spot Monitor Single User with Two Multiplexer1st Multiplexer Pin NoTwo Multiplexer with Slave Keyboard Controller Two Multiplexer with Slave Keyboard Controller method Two Multiplexer with Slave Keyboard Controller methodSW1 Setting Unit for TerminationSetting Address ID of Dome Camera Beyond ID 999, contact your service providerDome ID Off Function Setting Protocol of Dome CameraProtocol CameraConnection Alarm Display RAM Test Check NO. OK Check Aaaa OKGetting Started TitleHow to control On-Screen Menu Utility Accessing On-Screen Menu UtilityMenu ESCScan AUTOSCAN01 Auto Scan SetupEND Angle Quick moveJOY-LEFT to PREV. Save and Exitesc to Cancel Preset SetupFollow steps below to store the Preset positions AUTO/ ManualGuard Tour Setup Shortcut of Preset ProgramScan Type Normal DwellFollow steps below to program the Pattern Pattern Setup TitleArea Title Setup PRSTitle Start END ACB ==== Back Light SharpnessDigital Zoom Not at EDC-142E1EDC-143E WB white balance ControlAE Control Mode Line Lock ControlLocal Control Exit ESC to ExitLanguage Setup Home Function SetupFollow these steps to program the Home position OSD Display View Angle SetupView Direction Dome OSD DisplayFlip Panning RangeTilt Over Angle Initialize DataDome Reset TroubleshootingProblem Possible Solution System InformationWDR GlossaryShort Cut Key EDP SpecificationsAlarm inputs Alarm processingRemote control BackupDimensional Drawings