3.12Camera (Eighth Item of Main menu)

NOTE: The menu features will vary depending on the camera module installed in your dome camera.

 

CAMERA SETUP

 

FOCUS CONTROL

 

 

WB CONTROL

 

 

AE CONTROL

 

 

LINE LOCK CONTROL

 

 

SHARPNESS

: 9

 

BACK LIGHT

: OFF

 

DIGITAL ZOOM

: OFF (2x/4x/ MAX)

 

NIGHT SHOT CONTROL (optional)

 

SAVE AND EXIT (ESC TO CANCEL)

SHARPNESS

The higher the value, the more edges in the picture will be enhanced.

 

EDC-141E, EDC-142E, EDC-144E: 0~15

 

 

EDC-143E: 0~63

 

 

EDC-142E1, EDC-142E2: 0 ~ 20

 

BACK LIGHT

Objects in front of bright backgrounds will be clearer with BLC ON.

DIGITAL ZOOM

OFF: Zoom range is limited to the optical.

 

2x :

Zoom is extendable up to 2x of digital range.

 

4x :

Zoom is extendable up to 4x of digital range.

 

MAX:

Zoom is extendable Max digital Zoom range.

 

 

EDC-142E1, EDC-142E2: OFF, MAX

 

NIGHT SHOT CONTROL

(Not at EDC-142E1)

 

• FOCUS CONTROL

EDC-141E EDC-142E EDC-144E

FOCUS SETUP

MODE : AUTO

AF SENSITIVITY : HIGH EXIT(ESC TO EXIT)

EDC-143E EDC-142E1 EDC-142E2

FOCUS SETUP

MODE : AUTO/MANUAL

EXIT(ESC TO EXIT)

MODE:

AUTO / MANUAL Use manual mode in normal use.

AF SENSITVITY:

HIGH / LOW (only EDC-141E, EDP No. 74086; EDC-142E, EDP No. 74081; EDC-144E, EDP No. 74100)

HIGH:

Use this option when shooting fast motion.

LOW:

Offers better focus stability. In low luminance conditions, Auto Focus stops operation even when brightness changes, enabling stable

 

images of moving objects.

• CAUTION: Avoid continuous, 24-hour use of the auto focus. This may cause the lens to malfunction, and it will shorten the lifespan of the lens.

22

Image 22
Contents Installation and Operating Manual Contents Safety Instructions Introduction 1.1 FeaturesPush Bubble ring ass’y Screw Remove window Assemble bubble ring ass’yInstallation and Configuration 2.1 Package Contents Different version will not support alarm input and outputSTP AWG #24 Basic Configuration of Fastrax II Dome Camera SystemBNC 24VAC Single MultiplexerBNC BNC 1st Multiplexer Single User with Two Multiplexer1st Main Monitor Spot Monitor Pin NoTwo Multiplexer with Slave Keyboard Controller Two Multiplexer with Slave Keyboard Controller method Two Multiplexer with Slave Keyboard Controller methodSetting Unit for Termination SW1Beyond ID 999, contact your service provider Setting Address ID of Dome CameraDome ID Protocol Setting Protocol of Dome CameraOff Function CameraGetting Started Alarm Display RAM Test Check NO. OK Check Aaaa OKConnection TitleMenu Accessing On-Screen Menu UtilityHow to control On-Screen Menu Utility ESCEND Angle Auto Scan SetupScan AUTOSCAN01 Quick moveFollow steps below to store the Preset positions Preset SetupJOY-LEFT to PREV. Save and Exitesc to Cancel AUTO/ ManualScan Type Normal Shortcut of Preset ProgramGuard Tour Setup DwellPattern Setup Title Follow steps below to program the PatternPRS Area Title SetupTitle Start END ACB ==== Digital Zoom SharpnessBack Light Not at EDC-142E1WB white balance Control EDC-143EAE Control Local Control Line Lock ControlMode Exit ESC to ExitHome Function Setup Language SetupFollow these steps to program the Home position View Direction View Angle SetupOSD Display Dome OSD DisplayTilt Over Angle Panning RangeFlip Initialize DataProblem Possible Solution TroubleshootingDome Reset System InformationGlossary WDRShort Cut Key Specifications EDPRemote control Alarm processingAlarm inputs BackupDimensional Drawings